When the results of check item (3-14.11.) are "
01
"
(Detection of HPD is OK / Detection of RXSENSE is not OK )
When the results of check item (3-14.11.) are "
02
"
(Detection of HPD is not OK / Detection of RXSENSE is OK )
Check item(3-14.15.).
Checking the RXSENSE :
Does the test point of RXSENSE close to the HDMI output terminal
[
N1030
] indicate the (3.3V)?
N1030
HDMI OUT
[MONITOR2]
D2+ D2- D1+ D1- D0+ D0- CK+ CK-
Check item(3-14.16.).
Checking the HPD :
Does the voltage of HPD test point close to the HDMI output terminal
[
N1030
] indicate Hi (3-5 V)?
N1030
HDMI OUT
[MONITOR2]
HPD
Check the RXSENSE. (Monitor2)
Check the HPD. (Monitor2)
HDMI Tx [
U1039
] is faulty.
Replace with a new device.
HDMI Tx [
U1039
] is faulty.
Replace with a new device.
Recheck from
check item (3.3.).
If it does not work, replace the PCB.
Recheck from
check item (3.3.).
If it does not work, replace the PCB.
Check for a short circuit in the TMDS line.
If there is no problem, the HDMI Tx [
U1039
] is faulty.
Replace with a new device.
Check for a short circuit in the HPD line.
If there is no problem, the HDMI Tx [
U1039
] is faulty.
Replace with a new device.
NO
NO
YES
YES
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating
124