68
67
9. SERVICE PROGRAM
Factory Mode
With the following procedure, the Tracking Point, which is necessary for the adjustment and measurement of the tuner, can
be memorized.
1. Turn on the unit, press DVD, TUNER and MULTI ROOM key simultaneously more than three seconds.
2. "FACTORY MODE" will be displayed on the FLD for two seconds and the following frequencies will be stored in the
Preset Memory.
Band
Version
P1
P4
P3
P2
FM AUTO [MHz]
/N
90.0
98.0
106.0
87.5
Band
Scan Step
P5
P6
P7
P8
P9
P10
P11
P12
Other
AM [kHz]
9kHz(/N)
603
999
1404
531
No
Preset
MW / LW
603
999
1404
171
207
270
152
531
Microprocessor (CPU), DSP Version and FLD Segment Check Mode
Turn the unit into the Factory Mode (See above) first. Each time DISPLAY key on the remote control unit is pressed or
RC-5 code 161500 (Display) is entered, information shown on the FLD changes in the following order. Software versions of
µ-com and DSP can be seen and FLD segments can be checked.
1. Model Name is displayed like "SR-12S1:.
2. Software version of QU01(CPU) is displayed in the following format.
M
A
I
N
V
0
3
0
4
2
6
0
N
Year
Month
Date No
Ver.
3. Software Serial Number that is written in the factory is displayed.
S
E
R
I
A
L
X
X
X
X
X
X
4. Software Type Number is displayed
S
O
F
T
T
Y
P
E
X
X
(XX is displayed in Hex)
5. Group Type Number of the code that is written in the DSP’s external ROM is displayed.
C
O
D
E
-
G
T
Y
P
E
X
X
6. 1G and 2G of the FLD is lighted each other. (Character part of Dot Matrix stays off.)
7. Dot Matrix part of the FLD lights in the checker pattern. (Other part stays off.)
8. Code ID of the code that is written in the DSP’s external ROM is displayed.
C
D
X
X
X
X
X
X
X
X
X
X
Code No.
Device
Code Sig
Code Type
Version
ID
ID
ID
9. Returns to the step 1 and repeats the sequence.
10. Turn off power to quit Service Mode.
Note:
Step4, 5 is to check if CPU software is capable of DSP code. "Software Type No" is to show what "DSP Code Group"
CPU is capable of. And vice versa.
Step 8 is to manage the 16 codes for DSP.
* When the unit is once turned into Factory Mode, the unit keeps this mode until the main power is turned off.
(Turning into stand-by mode does not make it quit from Factory Mode.) When the unit quits from Factory Mode,
Information in the memory is also cleared and the unit returns to the status when it is out from the factory.
Product Reset
To reset the back up memory of the unit into the default status, follow the procedure below.
1. Turn of the unit and press CD-R/MD and AUX1 keys simultaneously more than three seconds.
2. After "DEFAULT" is displayed on FLD, power is turned off once and turned of again, EEPROM is cleared to the default
status, µ-com is reset and the unit returns to the normal status. (Software Serial Number will not be cleared.)
Note: When the unit is shipped from the factory, the procedure above must be done to set the unit to initial status after the
tests.
Summary of Contents for SR-12N1G
Page 25: ...39 40 PC04 QC08 QC04 QC02 QC01 QC03 QC07 QC06 QC05...
Page 29: ...45 QL08 QL09 QL12 QL10 QL13 QL15 QF04 QL04 QL18 QL20 QL16 QL11 QL07 QL17 PL04...
Page 30: ...46 QS02 QS01 PS04 DN07 QN04 QN06 DN05 P124 PP94 P824...
Page 32: ...48 QQ09 QQ04 QQ05 QQ06 QQ07 QQ08 QQ01 QQ03 QQ02 PQ04 PC64 QC60 QC61 P654...
Page 33: ...49 DF51 QF51 DF52 QF52 DF53 QF53 QF54 DF54 PF14 PP04 QP01...
Page 34: ...50 QX07 QX04 QX02 QX05 QX01 QX03 QX06 PX04 QS02 QS01 PS04...
Page 35: ...51 QS70 QS71 QS72 QQ71 QQ72 PS54 P814 Q802 Q801 Q811 Q803 Q812...
Page 36: ...52 DN09 DN06 DN08 P164 PY54...