31
32
11. TECHNICAL DESCRIPTION
Command Name
Code
SYS COM DATA START SYS
COM
DATA
Play
2053
20
53
11
10100 110101
Pause
2048
20
48
11
10100 110000
Cue
2059-10 20
59
10
11
10100 111011
1010
Stop
2054
20
54
11
10100 110110
FF
2052
20
52
11
10100 110100
FR(REW)
2050
20
50
11
10100 110010
Index+
2034
20
34
11
10100 100010
Index-
2035
20
35
11
10100 100011
Next
2032
20
32
11
10100 100000
Previous
2033
20
33
11
10100 100001
Pitch+
2038
20
38
11
10100 100110
Pitch-
2039
20
39
11
10100 100111
Pitch Bend+
2038-10 20
38
10
11
10100 100110
1010
Pitch Bend-
2039-10 20
39
10
11
10100 100111
1010
A-B
2059
20
59
11
10111 111011
Program
2041
20
41
11
10100 101001
Pitch On/Off
2037
20
37
11
1010 100101
Open/Close
2045
20
45
11
10100 101101
Time
2011
20
11
11
10100
1011
Mode
2036-10 20
36
10
11
10100 100100
1010
Preset
2041-12 20
41
12
11
10100 101001
1100
END monitor
2043-10 20
43
10
11
10100 101011
1010
CD-TEXT
2088
20
88
10
10100
11000
0
2000
20
00
11
10100
0
1
2001
20
01
11
10100
1
2
2002
20
02
11
10100
10
3
2003
20
03
11
10100
11
4
2004
20
04
11
10100
100
5
2005
20
05
11
10100
101
6
2006
20
06
11
10100
110
7
2007
20
07
11
10100
111
8
2008
20
08
11
10100
1000
9
2009
20
09
11
10100
1001
SERVICE 166363
16
63
63
11
10000 111111
111111
Connect
1856
18
56
11
10010 111000
Disconnect
1857
18
57
11
10010 111001
Decode
Binary
OUTPUT
INPUT
1
2 3
2
3
*
* *
*
*
Pin
Nam e
I/O
Active
1
PLAY TALLY
O
Low
2
PAUSE TALLY
O
Low
3
CUE TALLY
O
Low
4
STOP
I
Low
5
FR
I
Low
6
INDEX-
I
Low
7
PREVIOUS
I
Low
8
PITCH+
I
Low
9
PITCH ON/OFF
I
Low
10
FADER(NORMAL)
I
Low
11
INDEX
#2/ #3 TALLY
O
Low
12
+5V
-
---
13
FG COMMON
-
---
14
PLAY
I
Low
15
PAUSE
I
Low
16
CUE
I
Low
17
FF
I
Low
18
INDEX+
I
Low
19
NEXT
I
Low
20
END
I
Low
21
PITCH-
I
Low
22
FADER TALLY
O
Low
23
FADER(INVERT)
I
High
24
END TALLY
O
Low
25
TALLY COMMON
-
---
1. RC5 Code
This product is able to communicate to the other MARANTZ
products with the RCA Pin cable.
*
1 The service code is available during STOP mode only.
*
2 The Pitch Bend+ and Pitch Bend- are not available with
the digital out on.
*
3 The Pitch Bend+ and Pitch Bend- are not available on
PMD330.
5. GPI code
The GPI code is input from external controller with D-Sub 25
Pin connector.
*
The fader start is on during PLAY, and off during PAUSE.
*
The index is output by pulse signal.
When the index #2 is selected, the pulse signal of 200ms is
output at the top of index #2.
1 1 1 1 2 2 2 2 2 2 2
-------------
____
----------------
200ms
When the index #3 is selected, the pulse signal of 200ms is
output at the top of index #3.
2 2 2 2 3 3 3 3 3 3 3
-------------
____
----------------
200ms
3. Double spped Reading
The disc (spindle) motor of PMD331/340 rotates at double
speed for the Instant start & Anti-shock (shockproof) behavior
function.
The data that is read out at double speed from a CD is put into
the shockproof memory control & DRAM.
The data that is in the shockproof memory is forwarded to the
DAC and is played back at normal speed.
When it is set Digital Out to
"
ON
"
on the preset menu, the disc
(spindle) motor rotates at normal speed, and the data is read
at normal speed.
Therefore, Digital output is always outputted at normal speed.
PMD330 doesn’t have the shockproof memory control. There-
fore the disc (spindle) motor of PMD330 always rotates at nor-
mal speed.
Summary of Contents for PMD330