YES
YES
YES
YES
Check the I2C communication line. (HDMI Rx)
Check item(19).
Check the I2C communication line :
Check the CPU.
Is the "
I2C
" waveform of the TP near the HDMI Rx1 [
U1000
]
correct (like the one shown in the diagram) when the power is
turned on?
U1003
HSDA
HSCL
HDMI Rx2 [
U1003
] is faulty.
Replace with a new device.
HDMI Rx2 [
U1003
] is faulty.
Replace with a new device.
Recheck from
check item (1).
If it does not work, replace the PCB.
Check item(20).
Check the I2C com-
munication line :
Check HDMI Rx2 [
U1003
] patterns as
well as soldering.
If there is no problem, go to the next
step.
Check the HDMI Rx2.
Remove the damping resistor [
R1169/R1170
] of [
U1003
].
Is the "
I2C
" waveform correct?
Recheck from
check item (1).
If it does not work, replace the PCB.
NO
YES
NO
*The diagram shows an example.
(Signal patterns vary depending on the
timing.)
Points for checking waveforms
- Crest value (3.3V normally)
- Signal change
- SCL frequency (400kHz normally)
Voltage scale:1.0V/div
Time scale:10us/div
Before Servicing
This Unit
Electrical
Mechanical
Repair Information
Updating
97