2
Service Mode
1. While Mains cord is disconnected, press DISPLAY Button on the unit and plug in the Mains cord.
2. Version number of the front micom software is displayed.
3. Turn JOG dial to either direction then Display segment test begins.
4. First all the segments will light and then a segment turns off one by one.
5. Disconnect Mains cord to quit service mode.
Emargency Eject
1. Remove 5 screws on the top cover and remove
3. Disconnect the flexible wire.
the top cover.
4. Remove the MD mechanism component from the
2. Remove 4 screws on the bottom. (Pointed with
unit and remove the 4 screws on the both sides.
the arrows in the picture above.)
(Pointed with the arrows in the picture above.)
5. Slide the lever pointed with the arrow to the direction
6. Slide the pin pointed with the arrow to the direction
of the arrow.
of the arrow.
7. Disc is ejected.
2. SERVICE MODE
Summary of Contents for MD110
Page 11: ...9 10 3 WIRING DIAGRAM ...
Page 12: ...4 BLOCK DIAGRAM 11 12 ...
Page 13: ...13 14 5 SCHEMATIC DIAGRAM ...
Page 16: ...19 20 FRONT BOARD Q302 Q303 Q306 Q300 Q301 Q307 ...
Page 18: ...22 IC2 KIC9459N PIN CONNECTION PIN DESCRIPTION ...