Before proceeding with the installation, please reference the attached Installation drawings and
diagrams. These drawing show typical lengths and dimensions for short stroke and standard stroke hoist
installations of the 90KHz, 60KHz and 22KHz Sonar.
Before installing the Sea-Chest or Sonar it is IMPORTANT to measure the angle of a vessel during
typical search and catch situations as well as pitch and Roll measurements. Sea-Chests, that were
angled as much as 10° off the typical vessel angles during standard Sonar operation have been
observed in the past. This will make operation of OMNI Sonar very difficult and also reduces
performance greatly.
These issues should all be considered on installations in new or existing Sea-Chests.
Sea Chest and Hoist Size Listings
MODEL
60/90KHz
22KHz
Sea Chest Size
8”
18” pipe (Flange 16”)
Inside Diameter
Sea Chest Pipe
7.625” (194mm) to
7.981” (203mm)
16.8” (427mm) to
18” (406mm)
CONSULT FACTORY FOR MINIMUM SEA CHEST LENGTHS AS SHORT SEA CHEST MAY CAUSE EXCESSIVE
VIBRATION. CONSULT FACTORY WITH SEA CHEST DIMENSIONS FOR APPROVAL
FLANGE
60/90KHz
22KHz
Outside Diameter
13.7” (348mm)
23.6” (600mm)
Bolt Circle
Diameter
11.7” (297mm)
21.25” (540mm)
Flange Hole
Diameter
0.875” (22mm)
1.125” (28mm)
Number of Holes
8
16
Mounting Bolts
60/90KHz3/4”-10 x 3” SS
M18-2.5 x 70mm SS
1”-8x 4” SS
M24-3 x 120mm SS
HOIST
Short Stroke
60/90kHz
22kHz
Stroke
18” (457mm)
32” (813mm)
47.25” (1200mm)
Hoist Height
Above Flange
40” (1016mm)
52” (1320mm)
75” (1900mm)
INSTALLATION OF 22 KHz TRANSDUCERS IN 16” SEA CHESTS IS NOT RECOMMENDED. PLEASE CONSULT
FACTORY WITH SEA CHEST DIMENSIONS FOR APPROVAL
Summary of Contents for 22KHz
Page 1: ...MAQ SONAR COMPANY div of Helo Enterprises Inc Technical and Installation Manual ...
Page 6: ...Intentionally left blank for future use iv ...
Page 8: ...Intentionally left blank for future use vi ...
Page 10: ......
Page 16: ......
Page 17: ......
Page 18: ......
Page 19: ......
Page 20: ......
Page 22: ......
Page 23: ...60 90KHz Sea Chest 22KHz Sea Chest 11 ...
Page 24: ...GM4501 60 90kHz Transducer Pipe with Flange KA22005 22kHz Transducer Pipe with Flange 12 ...
Page 25: ...60 90KHz Sea Chest Guides 13 ...
Page 26: ...14 ...
Page 27: ...15 ...
Page 28: ...22KHz Sea Chest Guides 16 ...
Page 29: ...17 ...
Page 30: ...18 ...
Page 31: ...60 90KHz Hoist 19 ...
Page 32: ...22KHz Hoist 20 ...
Page 33: ...21 ...
Page 34: ...22 ...
Page 35: ...23 ...
Page 36: ...22KHz SHIELD INSTALLATION 24 ...
Page 37: ...25 ...
Page 38: ...26 ...
Page 39: ...27 ...
Page 40: ...PROCESSOR UNIT CASE DIMENSIONS TRANSCEIVER UNIT CASE DIMENSIONS 28 ...
Page 41: ...TRANSMITTER UNIT CASE DIMENSIONS JOYSTICK DIMENSIONS 29 ...
Page 42: ...UPPER HOIST CONTROL DIMENSIONS KEYPAD DIMENSIONS 30 ...
Page 43: ...OMNI INSTALLATION WIRING DIAGRAM 31 ...
Page 45: ...33 ...
Page 46: ...34 ...
Page 47: ...35 ...
Page 50: ......
Page 54: ......
Page 59: ...43 Operate Panel Setup Panel Display Panel Picture Panel Raw Data Panel Time Panel ...
Page 64: ......
Page 74: ...Intentionally left blank for future use 56 ...
Page 76: ......
Page 80: ......
Page 96: ......
Page 104: ......
Page 106: ...Intentionally left blank for future use 80 ...
Page 107: ...81 ...