background image

808 134th Street SW, Suite 120 • Everett, WA 98204 • USA • 425/745-3229

Fax: 425/745-3429 • E-mail: [email protected] • URL: www.maple-systems.com

8

7

4

5

Alarm

Ack

9

CLEAR

ENTER

6

Help

1

2

Page

Down

3

0

F3

F6

F2

F5

Del

F1

F4

Toggle

8

7

4

5

Alarm

Ack

9

CLEAR

ENTER

6

Help

1

2

Page

Down

3

0

F3

F6

F2

F5

Del

F1

F4

Toggle

INSTALLATION MANUAL

1010-0105, REV 03

Summary of Contents for OIT 3160B

Page 1: ...45 3429 E mail maple maple systems com URL www maple systems com 8 7 4 5 Alarm Ack 9 CLEAR ENTER 6 Help 1 2 Page Down 3 0 F3 F6 F2 F5 Del F1 F4 Toggle 8 7 4 5 Alarm Ack 9 CLEAR ENTER 6 Help 1 2 Page D...

Page 2: ...products and documentation at any time without notice IF SERVICE IS REQUIRED Package the unit in its original packaging container or if unavailable any suitable rigid container If a substitute contain...

Page 3: ...r operational software installed therefore The OIT will NOT operate until it has been configured using OITware 200 or STEPware 100 When power is first applied the OIT s display will indicate that it n...

Page 4: ...carefully if any shipping damage is evident notify the carrier immediately You are responsible for claimnegotiations with the carrier Save the shipping container and packing material in case the equip...

Page 5: ...x 7 dot matrix with cursor Display Character Size 2 lines of 20 characters 0 19 inches 4 8 mm high Display Viewing Angle Approximately 90 degrees Keypad Key Type Membrane switch with custom legending...

Page 6: ...bed in the National Electrical Code ANSI NFPA 70 WARNING Use only with Class 2 power source limited to 30 VDC open circuit and 8A short circuit 1010 0105 REV 03 6 OIT3160B 4160B 4 OIT Configuration Wi...

Page 7: ...ly as a general guide to be used in conjunction with the appropriate Class I Division 2 installation and wiring requirements The customer is ultimately responsible for proper installation Pay careful...

Page 8: ...PLC host control wires Never bundle the OIT cables together with 120 VAC power wires or with relay wiring Try to keep at least 8 inches 20 cm of separation between the OIT cables and other power wirin...

Page 9: ...le c Strip the insulation from the two insulated wires For the OIT end this is 0 27 inch 7 mm 1010 0105 REV 03 12 OIT3160B 4160B Figure 4 OIT3160 4160 Power Supply Connection Keep the lengths of the O...

Page 10: ...hat prevent the gasket from sealing properly The diagram in Appendix D shows the dimensions of the panel cutout required for proper installation This panel cutout illustration is shown actual size and...

Reviews: