Machine-side adaptation of the coolant supply to Form AD/AF
WARNING
Risk of burns from hot threaded pin area!
Serious burns and injuries can occur during heating and unscrewing the threaded pins.
Always wear ISO protective gloves when heating and unscrewing the threaded pins.
After heating, wait until the heated threaded pin area has cooled down.
The system for the coolant supply on tool holders to DIN ISO 7388 makes it possible to combine the common forms of cool-
ant supply into one machine-side tool body of Form AD/AF.
The system makes it possible to combine the following designs:
Form AD: Central coolant supply via through bore (normal setting)
Form AF: Central coolant supply via collar
To adjust the tool holder to the type of coolant supply on the machine, it is sufficient to adjust the position of two threaded
pins. The threaded pins (secured with thread locking compound) then seal off the bore for the alternative coolant supply.
WTE After-sales Service is also at your disposal for the changeover.