Power Supply / Battery 

 
The acquisition module operates from 2.1 to 3.6 Volts dc so can be supplied from a variety of cells.  

WARNING: It is important to note that the acquisition module is NOT reverse polarity protected! 

WARNING: The maximum voltage is 3.6V! 

 

Considerations When Selecting Batteries 

Re-chargeable or replacement 

This really depends on the application. Some applications where expected battery life with alkaline batteries 
will be many years would probably not warrant the use of re-chargeable batteries. Re-chargeable batteries 
have implementation issues such as how to connect to the charger, how to seal this connection if required, can 
the batteries be re-charged at a convenient point in the operation of the device I.E between shifts and does 
the voltage, when charging, exceed the maximum supply voltage of the acquisition module if so the inline 
charging module will need to be fitted. 
 

Required battery life 

Driven by the application and mainly dependent on measurement rate and sample time. The operation would 
normally require that the acquisition module is used in Low Power Mode to maximise battery life. 
 

Size of 

Choosing a battery will be influenced by how much space is available and what battery life is required, 
generally the bigger the battery the longer it will last. 
 

Operating temperature range 

A batteries useable capacity is influenced by its operating temperature. Generally, the lower the temperature 
the lower their ability to provide charge. Beware of the batteries specified operating range when considering a 
particular battery technology. 
 

Self discharge. 

Batteries are chemical devices and have a shelf life which needs to be considered in application where long 
battery life is required. Typically an Alkaline has a battery life of 5 years. 
 

Internal Resistance of battery 

Low internal resistance is important, the higher the resistance the less useful life of the battery is available. 
This is due to voltage drops caused during the high current phase of the measurement cycle. In the case of a 
T24-SAf strain gauge input module 300mA required for 250uS. Batteries with an internal resistance of less than 
150mOhm will not require the additional inline capacitor module. 
 

Connections to battery  

For the same reasons internal resistance must be low it is important to keep any voltage drops from the battery 
to the acquisition module as low as possible too. Care must be taken in selecting the connection method 
between batteries and acquisition module. For example cables should be kept as short and thick as possible. 
 

Environmental 

Other considerations when selecting a connection method to the Batteries is the effect of vibration. A standard 
battery holder is a poor choice in applications when the device can be subject to vibration. This is due to the 
interruption of supply from the battery to the acquisition module caused when the spring arrangement holding 
the battery to the terminal of the holder is defeated. 
Corrosion of terminals must also be considered as this will also introduce resistance into the supply 
connections. This could be overcome by ensuring the enclosure is sealed. 
 

Optimising battery life 

Battery life can be optimised by considering the following. 

 

Use of low power mode. 

 

Transmission interval. 

 

Required Measurement resolution (Sample time). 

 

Sleep / Wake configuration 

 

Auto-Sleep duration. 

 

Summary of Contents for T24-SAf

Page 1: ...T24 SAf Fast Strain Gauge Acquisition Module User Manual mantracourt com...

Page 2: ...d Restore 13 Data Provider Monitor 14 Advanced Settings 15 Installation 16 Overview 16 Power Supply Battery 17 Considerations When Selecting Batteries 17 Battery Types 18 Power Supply Modules 18 Lithi...

Page 3: ...power supply or batteries WARNING This module is not reverse polarity protected WARNING The maximum voltage is 3 6V Input Connections Strain Gauge Strain gauge connection is 4 wire as follows EXC SHL...

Page 4: ...e calibration feature is not available for the T24 SAf Installation T24 Toolkit To configure the devices we must use the T24 Toolkit software application This can be downloaded from our web site or ma...

Page 5: ...e Station Address In the toolkit all items that can be changed by the user are coloured orange To change a value just click on the relevant orange item You will then be presented with a new dialog win...

Page 6: ...he device Pairing removes the need to know the radio settings of the device you are connecting to and also ensures that it is in a suitable state for configuration Pairing Procedure Remove power from...

Page 7: ...or to diagnose poor communications issues This page shows the radio signal levels detected across all the channels available to the T24 series of devices Using this tool may help in detecting noisy a...

Page 8: ...a Provider Monitor page shown later in this manual T24 acquisition devices normally operate in low power mode and periodically transmit Data Provider packets This page shows all detected Data Provider...

Page 9: ...n Module User Manual 8 Information Once successfully paired to a device this page is displayed This page shows you information about the connected device Items you can change Name You can enter a shor...

Page 10: ...level currently set Usable Capacity This is not a parameter of the device but information used by the battery life guide This is the capacity of the battery in Amp Hours and has a profound effect on b...

Page 11: ...nge from 0 to 100 and within this band you should still achieve communications As the level drops towards zero communications may become intermittent but still achievable You can set the level at whic...

Page 12: ...this band you should still achieve communications As the level drops towards zero communications may become intermittent but still achievable RSSI is effectively the received dB level which will range...

Page 13: ...settings to match those of the analog output module NOTE Early acquisition module do not yet utilise the encryption keys so these should be left at all zeros Items you can change Channel Select a chan...

Page 14: ...d location to save the configuration file to All configuration information including calibration data will be saved to the file The file extension is tcf Restore Click this button to open a file dialo...

Page 15: ...the module transmitting data Continue Continue with data transmission Start Logging Allows you to select a filename and starts to log the data to the selected file The format of the file is CSV and t...

Page 16: ...Data Tag which is a 2 byte hexadecimal code By default this is set to the last 2 bytes of the device ID or to put it another way the last 4 characters of the device ID If by some chance you had two ac...

Page 17: ...hen selecting materials for product enclosures preference should be given to fibreglass light coloured ABS or Polypropylene at the wavelength of 2 4GHz radio other materials will adversely affect the...

Page 18: ...hen considering a particular battery technology Self discharge Batteries are chemical devices and have a shelf life which needs to be considered in application where long battery life is required Typi...

Page 19: ...dule to maximise usable capacity Lithium Primary 3 6V Li SOCl2 Lithium cells can be used but note that the maximum voltage is 3 6 Volts Select a cell with low internal resistance Example Saft LS17500...

Page 20: ...02 gauge wire attached to maximum load i e T24 SAf with four 350 Ohm strain gauges Note LED will only be lit when an input voltage is applied Suitable Batteries VARTA LIP653450 Rated Capacity 1100mAh...

Page 21: ...th high peak current acquisition modules such as a T24 SAf using the T24 Toolkit or power cycling when the battery is near the end of its life In normal operation Low power mode with an analog output...

Page 22: ...wo holes available for mounting The one nearest the connection pads can accept an M2 screw or American equivalent 0 80 Important Note DO NOT USE 2 screw size Note that the mounting hole is connected d...

Page 23: ...diagram below 7 mm 20 mm 20 mm External Antenna Option Use of a T24 external antenna requires a T24 acquisition module with a UFL connector stud in place of the on pcb antenna T24 acquisition modules...

Page 24: ...w 64 mm 58 mm 26 mm 20 mm The bulkhead mounting antenna can be used with metal or plastic housings Care must be taken when mounting the Antenna to ensure the installation does not become directional A...

Page 25: ...ms Maximum Gauge Sensitivity FR 3 2 mV V Offset Temperature Stability 1 4 ppm C Gain Temperature Stability 3 5 ppm C Offset Stability with Time 20 80 ppm of FR 1 Gain Stability with Time 30 ppm of FR...

Page 26: ...nde krav og andre relevante bestemmelser i EU directiv 1999 5 EC Portugu s Este equipamento satisfaz os requisitos essenciais e outras provis es da Directiva 1999 5 EC Suomalainen T m laite t ytt dire...

Page 27: ...nas may be used only with Approved Antennas that have been tested by mantracourt IC Labelling requirements for Industry Canada are similar to those of the FCC A clearly visible label on the outside of...

Page 28: ...Telemetry Product Range to which this declaration relates are in conformity with the appropriate standard EN 300 328 following the provisions of the Radio and Telecommunications Terminal Equipment Dir...

Page 29: ...sist you in resolving the problem If it is necessary to return the product to Mantracourt please include a note stating name company address phone number and a detailed description of the problem Also...

Page 30: ...log metrolog net tel 55 16 3371 0112 Distribuidor Brasil e Am rica do Sul CON TA TO Endere o Rua Sete de Setembro 2671 Centro 13560 181 S o Carlos SP Brasil Telefone 55 16 3371 0112 Fax 55 16 3372 780...

Reviews: