Mantracourt T24-DWS Quick Start Manual Download Page 3

 

 

Fast and Easy Setup

 

Simply put 

two D cell batteries

 in the wind speed sensor and apply 

power (8-36 Vdc) to the display.  
 

The display will 

automatically wake the  

wind speed sensor

 when it is powered up      

using the 

Power button

 

and will

 

sleep

 

when it is powered down. 
 

You can change the measurement units by pressing the 

Digit/mode 

button

. This will cycle through metres per second (

m/s

) and miles per 

hour (

mph

). There is a small enunciator at the bottom of the display 

showing which units have been selected. The display will show the 10 
second average wind speed at the default setting of once per second 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
The 

buzzer/relay set point

 is set using the buttons on the display. Press 

and hold the 

Digit/Mode 

button until all seven digits are shown.  

 
Short presses on the 

Digit/Mode

 button selects the digit to change and 

the 

up/down

 keys change the number. Press and hold 

Digit/Mode 

again to save the changes.  This is factory set to 55.9 m/s (125 mph) 

Digit Mode Button 

Use this to change the 

measurement unit. 

 

Press and hold this button 

to set the buzzer / relay 

set point 

Power Button 

Powering on and off wakes 

and sleeps the wind speed 

sensor 

Up/Down Keys 

Used to change digits 

Summary of Contents for T24-DWS

Page 1: ...Wind Speed Sensor and In Cab Display Quick Start Guide When bought as a set the T24 DWS and T24 WSSP are paired and will work as a system straight out of the box for ease of use...

Page 2: ...2...

Page 3: ...have been selected The display will show the 10 second average wind speed at the default setting of once per second The buzzer relay set point is set using the buttons on the display Press and hold t...

Page 4: ...connect power source The DWS is detected and paired to the Toolkit There are various tabs in the Toolkit including the Info page Save and Restore Radio settings and LQI The Advanced page allows us to...

Page 5: ...5 Note the Paired Data Tag is the last 4 digits of ID number by default This can be set to Data Tag 1 to only show gust when it has been enabled in the T24 WSSP see page 3...

Page 6: ...verage since last transmission The transmit interval is factory set to 1000 ms and the average sample period is factory set to 10 seconds There is also an option of the WSS sending the gust value on t...

Page 7: ...ensor is pre calibrated but the Units tab allows us to change the units that the wind speed sensor outputs Note The DWS will only accept a m s input and will display an error ERROR3 on the display if...

Page 8: ...8 The advanced tab allows you to change more settings but this usually won t be required if you are using the DWS...

Page 9: ...er Check the power source batteries or wired connection Check the JP1 connection The link should join the two pins The LED isn t illuminated This is only relevant for a wind speed sensor that has a wi...

Page 10: ...10 Notes...

Page 11: ...11 Notes...

Page 12: ...DWS Applies To Wind Speed Sensor System Part Number 517 216 Issue Number 01 01 Dated 22 October 2018 In the interests of continued product development Mantracourt Electronics Limited reserves the rig...

Reviews: