Mantracourt Electronics Limited
DCell & DSC MantraCAN User Manual
58
The compound used must be specified for electrical use, and have sufficient thermal conductivity to cope with the
heat given off (up to 1W on a 15V supply).
DSC
no additional electrical shielding is required, but moisture and/or mechanical protection are often required.
Any simple box or enclosure can be used. If metal, the enclosure should be earthed to the SH connection (see