Mantracourt Electronics Limited
DCell & DSC MantraCAN User Manual
53
Chapter 9 Software Command Reference
This chapter contains tables of all DCell/DSC commands, with brief details of each.
Commands in Access Order
Name
Description
Access
Command Number
CMVV
Temp Compensated mV/V
RO
5
STAT
Status
RO
6
MVV
Filtered & factory calibrated mV/V
RO
8
SOUT
Selected output (copy of SYS)
RO
9
SYS
Main output
RO
10
TEMP
Temperature
RO
11
SRAW
Raw System output
RO
12
CELL
Cell output
RO
13
FLAG
Error flags
RW
14
CRAW
Raw cell output
RO
15
ELEC
Electrical output
RO
16
SZ
System zero
RW
22
SYSN
Snapshot result
RO
23
PEAK
Peak value
RO
24
TROF
Trough value
RO
25
CFCT
Communications failure count
RW
26
VER
Software version
RO
30
SERL
Serial number low
RO
31
SERH
Serial number high
RO
32
RATE
Reading rate select
RW
36
NMVV
Nominal mV/V for scaling ELEC
RW
39
CGAI
Cell gain
RW
40
COFS
Cell offset
RW
41
CMIN
Cell range min
RW
44
CMAX
Cell range max
RW
45
CLN
Number of Linearisation points
RW
50
CLX1..7
Linearisation raw-values
RW
51..57
CLK1..7
Linearisation corrections
RW
61..67
SGAI
System gain
RW
70
SOFS
System offset
RW
71
SMIN
System range min
RW
74
SMAX
System range max
RW
75
USR1..9
User storage values
RW
81..89
FFLV
Dynamic Filter Level
RW
92
FFST
Dynamic filter steps
RW
93
RST
Reset
X
100
SNAP
Take snapshot
X
103
RSPT
Reset peak & trough
X
104
SCON
Shunt cal ON
X
105
SCOF
Shunt cal OFF
X
106
OPON
Digital Output on
X
107
OPOF
Digital output off
X
108
CTN
Number of Temperature Compensation points
RW
110
CT1..5
Temperature Compensation Point
RW
111..115
CTG1..5
Temperature Compensation Gain adjust
RW
116..120
CTO1..5
Temperature Compensation Offset Adjust
RW
121..125
STRMON
Start Data Streaming
X
128
STRMOFF
Stop Streaming Data
X
129