![Mantis BF28BM-4 Installation Instructions Manual Download Page 15](http://html1.mh-extra.com/html/mantis/bf28bm-4/bf28bm-4_installation-instructions-manual_1723777015.webp)
27297-1-1010
Page 15
COLINEAR TRANSITION VENT KIT
The Colinear Transition Kit (Part number PVCT) is available
and can be used to secure the flue and inlet pipes from the
Mantis. When venting vertically, the exhaust pipe termina-
tion must be a minimum of 3 inches above the air inlet.
The flue can be terminated with a PTrap or two 90° elbows.
The Vertical Termination Cap (Part number PVVTC) can
also be used to terminate the flue pipe when using the Co
-
linear Transition Kit.
AIR INTAKE
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
TRANSITION PLATE
PVC CEMENT
PVC CEMENT
OUTDOOR SEALER REQUIRED
OPTIONAL
TERMINATION CAP
3” MIN.
REQUIRED HEIGHT IS 12” MINIMUM.
IT IS RECOMMENDED TO BE 12” ABOVE
THE MAXIMUM EXPECTED SNOW LEVEL.
AIR INTAKE
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
TRANSITION PLATE
PVC CEMENT
PVC CEMENT
OUTDOOR SEALER REQUIRED
3” MIN.
EXHAUST
PTRAP OR 2 90° ELBOWS
SUPPLIED BY INSTALLER
REQUIRED HEIGHT IS 12” MINIMUM.
IT IS RECOMMENDED TO BE 12” ABOVE
THE MAXIMUM EXPECTED SNOW LEVEL.
Installation of the Colinear Transition Plate
1. Attach the plate to chimney chase, flat roof, or outside
wall with four (4) screws. Use outdoor sealant to seal
the transition plate to the surface.
2. Both inlet air pipe and flue exhaust pipe must be
12 inches from the roof line, and it is recommended to
be 12 inches above the maximum snow line. Also refer
to local codes. See Figures 11 and 12.
3. Attach the flue and inlet air pipes to the transition plate.
Use the appropriate primer and cement to permanently
bond the joints and the pipes to the transition plate.
Figure 11
Figure 12
VENT ADAPTOR KITS
The Vent Adaptor Kits provide a transition from the appli
-
ance to the flue and inlet pipes. Colinear Adaptor (part
number PVCA) provides a transition for the inlet air. When
using the flue adapter, use the appropriate primer and ce
-
ment to permanently bond the joints and the pipes. The
inlet air pipe does not need to be cemented.
FLUE ADAPTOR
PLASTIC GASKET
INSTALL FOAM GASKET
THREADED CONNECTOR
Figure 14
Figure 13