12
6.1. External accessories connection
Function
Functionality
description
Peripherals
characteristics
Abbreviation N°
Terminal / Connection description
C1
Power
supply
It allows to
supply the
product
80
– 264 VAC
47
– 63 Hz
65 W
L
Live
N
Neutral
Protecting Earth
C2
Opening
control 1
It allows to use
an external
command
(pushbutton,
non-contact
pushbutton,
radar, security
cell, etc.)
Power
consumption
1 A max
(5 W in 24 V)
24 V
1
External command power
GND
2
INPUT 1
3
Door opening (link with GND)
GND
4
Common wire used for TEST,
SAFETY and INPUT
SAFETY 1
5
The door stays open if it’s not
connected to GND
TEST 1
6
Connect the input Test radar
(necessary to be conform with the
EN16005 standard)
C3
Opening
control 2
It allows to use
an external
command
(pushbutton,
non-contact
pushbutton,
radar, security
cell, etc.)
Power
consumption
1 A max
(5 W in 24 V)
24 V
1
External command power
GND
2
INPUT 2
3
Door opening (link with GND)
GND
4
Common wire used for TEST,
SAFETY and INPUT
SAFETY 2
5
The door stays open if it’s not
connected to GND
TEST 2
6
Connect the input Test radar
(necessary to be conform with the
EN16005 standard)
C4
Lock
It allows to use
a locking
system with a
power applied
or removed
(suction or
electromagnet)
Power
consumption
500 mA max
(12 W in 24 V)
N.O.
1
Connect it if the system is locked
without power supply
N.C.
2
Connect it if the system is locked
with power supply
24 V
3
Connect one of the two wires of
the lock