Manson Engineering Industrial MP-3722 User Manual Download Page 1

 PV Charge Controller

MP-3722

User's Manual

Table of Contents

Precautions and Specifications          

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 1

1. Introduction                

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 2

2. Control and Indicator         

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 2

3. Installation and Indication              

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 3

3.1

  Connection

          

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 3

3.2

  LED Indicator

     

              

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 3

3.3

  LCD Display

       

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 4

3.3.1

  LCD Display Sequence

    

              

 

            

 

            

 

            

 

            

 

            

 

            

 

 4

3.4

  The Dip Switch, Set-Buttons and Reset Button Functions

       

 

            

 

            

 

            

 

 4

3.4.1

  Adjust the PV Charge Controller Settings

          

 

            

 

            

 

            

 

            

 

 4

3.4.2

  Select the Auto/Manual Equalization charging and Night-Light Mode

              

 

 6

4. PV Charge Control Mode   

              

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 6

4.1

  3-Stage Charge Control

  

             

 

            

 

            

 

            

 

            

 

            

 

            

 

            

 

 6

4.2

  Equalization Charging Mode (Automatic or Manual)

   

              

 

            

 

            

 

            

 

 6

4.2.1

  Automatic Equalization Charging

           

 

            

 

            

 

            

 

            

 

            

 

 6

4.2.2

  Manual Equalization Charging

    

              

 

            

 

            

 

            

 

            

 

            

 

 6

4.3

  12V DC Load Terminal- Control Mode

            

 

            

 

            

 

            

 

            

 

            

 

 7

4.3.1

  Low Voltage Disconnect (LVD)

              

 

            

 

            

 

            

 

            

 

            

 

 7

4.3.2

  Low Voltage Reconnect (LVR)

   

              

 

            

 

            

 

            

 

            

 

            

 

 7

4.3.3

  Night-Light Mode Programs

       

 

            

 

            

 

            

 

            

 

            

 

            

 

 8

4.4

  Temperature Sensor (Optional)

               

 

            

 

            

 

            

 

            

 

            

 

            

 

 8

4.5

  Over Temperature Protection

     

              

 

            

 

            

 

            

 

            

 

            

 

            

 

 9

5. Remote Signal Terminal (Optional)          

 

            

 

            

 

            

 

            

 

            

 

            

 

 10

Summary of Contents for MP-3722

Page 1: ...arge Controller Settings 4 3 4 2 Select the Auto Manual Equalization charging and Night Light Mode 6 4 PV Charge Control Mode 6 4 1 3 Stage Charge Control 6 4 2 Equalization Charging Mode Automatic or...

Page 2: ...use explosion Cover wrench handles with plastic tape or vinyl dip coating material Specifications Models MP 3722 Battery voltage 12V Maximum PV panel open circuit voltage 26V Continuous load charge cu...

Page 3: ...tage Disconnect and Low Voltage Reconnect Build In Microprocessor for PV charge control to maximize the charging efficiency Overcharge and Over discharge Protection Over Temperature Protection Short C...

Page 4: ...ler should be installed in a dry sheltered location away from sources of high temperature and moisture 3 2 LED Indicator Red Flashing Battery Voltage is lower than 12 6V Constant Red Battery Voltage h...

Page 5: ...the total Ampere Hour input to the system in current day L1D PV_AH Shows the total Ampere Hour input to the system a day before L2D PV_AH Shows the total Ampere Hour input to the system 2 days before...

Page 6: ...rer s specific recommended values How to adjust the Bulk Float Charge Voltage LVD LVR and Night Light Mode 1 First take out all the connections to the PV controller except those to battery 2 Push up t...

Page 7: ...ation Eq charging is only for wet type Lead Acid Battery When Auto Equalization Charging is set at ON mode Equalization charge will occur for 2 hours once every thirty days Use the dip switch to selec...

Page 8: ...age Setting for one full hour with various rapid On Off pulses PWM It then switches to Float Charge Mode c FLOAT CHARGE The controller will maintain the battery voltage at the float voltage setting by...

Page 9: ...ce and the controller will return to the charging mode before the Equalization charge 4 3 12V DC Load Terminal Control Mode The 12V DC load terminal is designed for low power DC load such as street li...

Page 10: ...in Z hours before sunrise Dusk to Dawn Load is turned on all night Measure Night Length The load timer options that turn the load on again before sunrise require that the PV charge controller to measu...

Page 11: ...rotection The operation temperature of the transistors of the PV Charge Controller is also continuously monitored If excessive temperature is detected the charge controller transistors will repeatedly...

Page 12: ...e battery status Red LED See Section 3 2 Pin 8 4 Shows the battery status Green LED See Section 3 2 Table 7 Pins configuration Note Pin 3 and 5 are not used in Remote signal Terminal Rev 2 0 05 2009 7...

Reviews: