Manson Engineering Industrial HCS-3600 USB User Manual Download Page 2

5  .    

  CONTROLS AND INDICATORS

 

 

(1) LED panel meter display with CC/CV Indictor
(2) Rear Control Indicator 

(lights up when using Preset/ Remote Control/ Set mode)

(3) Output Voltage Control Knob 

(control both the main and auxiliary output voltage)

(4) Output Current Control Knob 

(control both the main and auxiliary output current limit)

(5) Power ON/OFF Switch
(6) Aux. output terminal (max 5A)

Note:

HCS-3600: The total rated current (Aux.+Main) is 60A
HCS-3602: The total rated current (Aux.+Main) is 30A
HCS-3604: The total rated current (Aux.+Main) is 15A

(7) Output Terminal 

(Rated 60A for HCS-3600/ Rated 30A for HCS-3602/ Rated 15A for HCS-3604)

(8) Remote Sensing Terminal 

(for model HCS-3600 only)

(Warning!:  Shorting  the  remote  sensing  terminal  or  Connect  sensing  terminal  in  reverse  polarity  will
damage the power supply)

(9) Mode Selection Switch 

(Normal, Preset, Remote Control, Set Modes)

(10) Recall Selection Switch
(11)  Remote Control Terminal
(12) Cooling Fan Air Intake Grille
(13) AC Input Plug

Front

Rear

Summary of Contents for HCS-3600 USB

Page 1: ...o not operate or touch this power supply with wet hands Do not open the casing of the power supply when it is connected to ac mains Refer all servicing to qualified service personnel only Before replacing the AC fuse at AC socket find out and clear up the cause first Replace the AC fuse with the same type and rating as the original fuse The max output voltage of Model HCS 3604 is over 60VDC avoid ...

Page 2: ...3600 The total rated current Aux Main is 60A HCS 3602 The total rated current Aux Main is 30A HCS 3604 The total rated current Aux Main is 15A 7 Output Terminal Rated 60A for HCS 3600 Rated 30A for HCS 3602 Rated 15A for HCS 3604 8 Remote Sensing Terminal for model HCS 3600 only Warning Shorting the remote sensing terminal or Connect sensing terminal in reverse polarity will damage the power suppl...

Page 3: ... 15V HCS 3602 25V HCS 3604 55V Maximum 6 3 Set Mode First enter into the Set Mode by pushing Switch 9 to Set Mode slot The power supply is then ready to be preset 6 3 1 To define the preset output P1 P2 P3 a Select the Recall Switch 10 to the position P1 P2 or P3 which you want to set b Adjust the front panel voltage control knob to set your desired voltage value c Adjust the front panel current c...

Page 4: ...d make sure it complies with your AC mains voltage Connect the power supply to the AC Mains using the provided power cord Make sure the Mode Switch 9 is at Normal Position Below table to show the self test sequence Self test display and Sequence Test contents To show software version Segment check C V Indicator check C C Indicator check Rear control indicator check Return to C V Start to check Ove...

Page 5: ...rity input of the equipment 7 6 Switch on the power supply first and the panel meter green CV Indicator should light up again 7 7 Switch on the equipment and the panel meter green CV Indicator should still remain in green 7 8 You can now operate the equipment When an operation is finished switch off the equipment first and then switch off the power supply 8 REMOTE SENSING ONLY HCS 3600 HAS THIS FU...

Page 6: ...put voltage range of the power supply by varying the external voltage source Short circuit the main output with 8AWG wire to check the display for CC setting varying the external voltage source 9 2 Method B Using two 0 5K Ohm variable resistors Remark variable resistors 5Kohm Remote Socket Pin Assignment for variable resistor PIN FUNCTIONS REMARKS 1 Internal DC 5V Resistor end 2 Voltage Adjust Var...

Page 7: ...e modes Normal Preset Remote and Set mode A By default Pin 5 is open and output is on B Shorting Pin 5 to Pin 4 ground and output is off C When output is off the LED will show OP OFF Remark using the 8pin remote plug provided and connect with 22AWG wires Pin numbers are marked on the black portion ...

Page 8: ...unit and remove all loading Check your load and output setting Allow the unit to cool down for at least 30 minutes Check if any of the ventilation is blocked check enough clearance around power supply Listen carefully for the short wind noise from the cooling fan when you turn on the unit again If you cannot hear this routine self test wind noise on switch on the fan is fault and do not use the po...

Page 9: ...4 5A Efficiency 85 86 88 Switching Frequency 65 85Khz 75 95Khz 65 85Khz Tracking Over Voltage Protections O P 1 5V set voltage 2V O P 5 15V set voltage 3V O P 1 5V set voltage 2V O P 5 20V set voltage 3V O P 20 30V set voltage 4V O P 1 5V set voltage 2V O P 5 20V set voltage 3V O P 20 60V set voltage 4V Transient Response Time 50 100 Load 1 5ms Power Factor Control Power factor correction 0 95 at ...

Reviews: