Installation Instructions

 

Specifi cations are subject to change without notice  

Page 3

[email protected] | www.manrose.co.nz 

Distributed by Simx Limited

Through Roof Fan Cowls and Fan Kits

For inline centrifugal fan models: 
FAN2120 / FAN2122

Brown

Blue

Green/Yellow

P

N

E

2.0    F
CAP

Motor

Black

Fasten tube to roof truss or rafter using clamp bracket supplied. 
Tube/cowl must be mounted vertically to ensure weatherproofi ng

Fix diffuser to ceiling and fasten ducting. If screw-fi xing diffuser is 
supplied cut 153mm diameter hole. If diffuser is type with spring 
loaded self-latching clip fasteners cut 205mm diameter hole.

Make electrical connections below roof

Flexible ducting connects directly to the 
bottom of rigid duct. Cut any excess 
length of ducting off before connecting.

WIRING CONNECTIONS

TYPICAL INSTALLATION

Black

Blue

Green/Yellow

P

N

E

2.0    F
CAP

Motor

Brown

For inline high performance centrifugal fan models: 
FAN2121 / FAN2123

White

White

NOTE

•  The roof fl ashing supplied is not suitable for fi tting directly on to tiled roofs.

•  As per the E2 Building Code, a roof soaker fl asher plate is required for roof penetrations greater than 60mm diameter.  

 

 

 

Please refer to E2 Building Code for more details.

Summary of Contents for FAN2120

Page 1: ...rminations are completed the rigid duct can then be fastened to a rafter or purlin with the supplied clamp for rigidity Ducting connections can then be made Precautions must be taken to avoid the back flow of gases into the room from the open flue of gas or other fuel burning appliances Please ensure these instructions are read thoroughly before commencing installation and that all documentation i...

Page 2: ... ventilation The Building Code is enshrined in law The New Zealand Building Code G4 has been changed This is supported by Acceptable Solution G4 AS1 Fourth Edition that specifies mechanical ventilation in accommodation units that contain cooktops showers and baths Residential Tenancy Regulations to the Healthy Homes Standards Residential Tenancy Regulations for rental properties only is changing t...

Page 3: ...d cut 153mm diameter hole If diffuser is type with spring loaded self latching clip fasteners cut 205mm diameter hole Make electrical connections below roof Flexible ducting connects directly to the bottom of rigid duct Cut any excess length of ducting off before connecting WIRING CONNECTIONS TYPICAL INSTALLATION Black Blue Green Yellow P N E 2 0 F CAP Motor Brown For inline high performance centr...

Page 4: ... 280mm diameter hole in the roofing with minimal clearance for the tube Insert the tube through the hole Apply a neutral cure silicon sealant on the underside of the flange Turning the flexible flange back makes this simple Press the roof flashing into the contours of the roof configuration Fasten the roof flashing to the roof using the tek screws supplied Drill a 5mm clearance hole in the flange ...

Page 5: ...nto the top of the tube Alternatively use the small roof flashing to run the cable through the roof panels at a suitable location If required cut all the way down the flashing to pass cable through Crimp metal clips onto the lip of the flashing to reseal Fit the small roof flashing in the similar fashion to the large one EXTRACT AIR SUPPLY AIR Place the fan or cowl onto the top of the tube The air...

Reviews: