PLEASE DISPOSE OF
USED FAN AT YOUR
LOCAL CIVIC AMENITY
SITE. DO NOT DISPOSE
IN DOMESTIC WASTE
077635
09/15
SWITCHED LIVE
NEUTRAL
LIVE
TIMER FANS
Single speed with overrun timer. When switched ‘ON’, the fan will operate at full speed and will continue to run
for a pre-set time after the switch is turned ‘OFF’.
TIMER ADJUSTMENT - BEFORE ADJUSTING THE TIMER, SWITCH OFF THE MAINS SUPPLY.
1. Remove the fan grille. The controller is factory set at 15 minutes approx. The overrun time period can be
adjusted from 5-25 minutes by altering the adjuster on the control PCB.
2. To REDUCE the operating time, use a small screwdriver to turn the adjuster ANTI-CLOCKWISE.
3. To INCREASE the operating time, use a small screwdriver to turn the adjuster CLOCKWISE.
4. Replace the fan grille.
SERVICING AND MAINTENANCE.
1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build
up of dirt or other deposits.
2. Carefully push the front panel of the grille upwards away from the base part of the grille.
Wipe the inlets and front face with a damp cloth until clean.
The fan has sealed for life bearings, which do not require lubrication.
N
L
N
L
S/L
Pullcord
Switch