background image

PLEASE DISPOSE OF
USED FAN AT YOUR 
LOCAL CIVIC AMENITY
SITE. DO NOT DISPOSE
IN DOMESTIC WASTE

077635

09/15

SWITCHED LIVE
NEUTRAL
LIVE

TIMER FANS
Single speed with overrun timer. When switched ‘ON’, the fan will operate at full speed and will continue to run 
for a pre-set time after the switch is turned ‘OFF’.

TIMER ADJUSTMENT - BEFORE ADJUSTING THE TIMER, SWITCH OFF THE MAINS SUPPLY.

 

1. Remove the fan grille. The controller is factory set at 15 minutes approx. The overrun time period can be 
adjusted from 5-25 minutes by altering the adjuster on the control PCB.
2. To REDUCE the operating time, use a small screwdriver to turn the adjuster  ANTI-CLOCKWISE.
3. To INCREASE the operating time, use a small screwdriver to turn the adjuster  CLOCKWISE.
4. Replace the fan grille.

SERVICING AND MAINTENANCE.

1. At intervals appropriate to the installation, the fan should be inspected and cleaned to ensure there is no build 

up of dirt or other deposits. 

2. Carefully push the front panel of the grille upwards away from the base part of the grille. 
Wipe the inlets and front face with a damp cloth until clean. 
 
The fan has sealed for life bearings, which do not require lubrication.