1. Loosen screw.
2. Pull grille
slightly away
from bottom
edge.
3. Push grille upwards until
clear from the fan chassis.
WIRING.
WARNING: THE FAN AND ANCILLARY CONTROL EQUIPMENT MUST BE ISOLATED FROM THE
POWER SUPPLY DURING THE INSTALLATION / OR MAINTENANCE.
• The cross - sectional area of supply cord used should be ranged from 1 - 1.5mm2.
• Cable entry can only be made from the rear of the fan.
• The extraction fan is suitable for connection to 220-240V 50Hz supply.
• The fan is a class II double insulated product and MUST NOT be earthed.
1. Select and follow the appropriate wiring diagram.
2. Check all connections have been made correctly and ensure all terminal connections and cable clamps are
securely fastened before switching on the electrical supply.
NEUTRAL
LIVE
STANDARD FANS - Controlled by remote switch (e.g. light switch or auto sensor).
N
L
N
L
Pullcord
Switch