Before connecting the hose to the tool please check, whether the hose and the
quick coupler are clean. Do this by letting air run freely through hose and quick
coupler, It is absolutely necessary, that quick coupler and hose have a sufficient
diameter. Please note, that the hose is never too big, but mostly too small! For
type RRI-40A an internal diameter of the hose of 6,5 mm is recommended.
Air pressure at the inlet of the tool during running has to be at the maximum of 6.3
bar. When this pressure is exceeded, unnecessary wear and/or damage will
occur. At the pressure of below 5.5 bar power loss will occur and if the pressure is
excessively low, also additional wear/damage will occur.
The quality of the compressed air must be good, which means clean, dry and this
is best assured by means of an air filter. We advise the use of a complete FRL
(filter, regulator, lubricator) unit. The oiler has to be adjusted to approx. 3 to 6
droplets per minute. The air hose between oiler and tool should never exceed a
length of 6 to 8 meters.
In those cases, where it is possible, use of a centralized oiler is recommended by
us. This system will allow use of less oil and assure a perfect lubrication. When
using a centralized oiler, oil consumption can be reduced by up to 80%.
If you intend not to use the tool for a longer period of time, it has to be oiled.
Please fill some droplets of resin and acid free oil into the air inlet and let the tool
run free for a couple of seconds.
Safety
Do not ignore safety precautions.
Do not modify this tool in any way, this can cause danger for the operator.
Make sure that this manual is accessible at all times for any relevant person, in
case of loss of this manual ask your dealer for a new copy.
Make sure that during operation of the tool no projectiles can be generated, this
can be dangerous and may cause injuries.
Make sure that the work piece is securely fixed.
Make sure that the inserted tool or accessory is mounted correctly, if not it may
cause high speed projectiles.
Make sure that no dangerous circumstances can occur for other persons in the
work area.
Always wear safety glasses during operation of the tool. The grade of protection
must be in relation to the risk of the operation.
Rotating mounted accessories can be easily entangled by rubber coated or metal
reinforced gloves. Wear suitable gloves.
Keep fingers out of reach of the inserted tool or accessory
Never hold the drive shaft, socket, bit, inserted/mounted tool/accessory with your
hands while rotating.