TRI-LOCK OPERATION AND MAINTENANCE

TRI-DIM

15

Appendix B

 

Locking Tray

LOCKING TRAY CHANGE OUT 

It is advised that any locking tray mechanism replacement or 
change out be done in a decontaminated environment. Due to 
sharp edges, placing a metal locking tray in a PVC bag is not 
recommended. However, one of the advantages of the Tri-Lock 
BG/BF bag-in/bag-out contamination housing is the ability to 
change out locking trays in the field. 

Change out is a simple task. The same concept applies to locking 
mechanisms as that to filters (refer back to start up procedures).

First, remove all filters from the contamination unit following the 
Start Up Procedures aforementioned. Insert a new bag with a 
standard ratchet with a ½” socket in the bag. For Gel seal units a 
3/8” socket will be needed as well. Position the new PVC bag’s 
shock cord the same way you would for a PVC bag with a new filter 
in it. Remove the old bag stub in the new bag.

FLUID SEAL METHOD 

1. 

Using the ratchet with the ½” socket remove the two hex nuts 

and washers for both the top and bottom locking trays.

2. 

Then switch to the 3/8” socket and remove the hex nut and 
washers from the linkage to the door swing arm.

3. 

Remove both the top and bottom parts to each pair of locking 
trays and pull into the PVC bag.

4. 

Treat the locking mechanism as a dirty filter and continue the 

appropriate steps.

Warning! 

Ratchet and socket must remain in the bag.  

Do not remove.

GASKET SEAL METHOD  

1. 

Using the ratchet with the ½” socket remove the two hex nuts 

and washers for both the top and bottom locking trays.

Fig. 21:

 Downstream view of locking tray mechanism

2. 

Lift the top half of each locking tray off of the studs and into 
the bag.

3. 

Remove the pipe bearings from the locking mechanism and 
back off the drive bolts to release the bottom locking trays.

4.

 Remove the bottom-locking tray and pull into the PVC bag.

5.

 Treat the locking mechanism as a dirty filter and continue the 

appropriate steps.

Warning! 

Ratchet and socket must remain in the bag.  

Do not remove.

Summary of Contents for TRIDIM Tri-Lock BF

Page 1: ...Tri Lock BG BF Operation Maintenance Manual...

Page 2: ...Tri Lock BG BF Operation Maintenance CONTENTS Manufacturer s Message 3 Introduction 4 Fluid Seal 5 Gasket Seal 6 Filter Elements Care and Housing Installation 7 Start Up Procedures 8 Appendix A Operat...

Page 3: ...ncepts of installing a new filter s into a new system and replacing dirty filters in systems that are already in operation Once theconceptisunderstood bothmaintenance personnel and safety personnel ca...

Page 4: ...ut ring over which a heavy duty plastic bag is attached see picture below Once the initial filters are installed and the first bag attached all filters both dirty and new are handled through the bag u...

Page 5: ...filter face DESCRIPTION OF FLUID SEAL FILTER LOCKING SYSTEM The fluid seal Tri Lock BF bag in bag out housing has a filter locking arm in each tier to operate the replaceable filter locking mechanism...

Page 6: ...housing independent pressure bars with preloaded springs located in the filter locking mechanism force the filter against the interior mounting frame there are two drive bolts per filter Preloaded spr...

Page 7: ...of filters is prohibited Moving of filters should be restricted for fear that the media will become damaged Shelf life is no more than three years for both gasket and gel seal filters see manufacturer...

Page 8: ...flow device will cause bag to suck tight against filter s and possibly cause damage to the bag Consult with safety officer and perform both a job safety analysis prior to installing or removing any fi...

Page 9: ...door of the tier to rest the HEPA filter 4 Provide Bag Provide one new factory specified PVC bag for each filter tier Always inspect bag for rips and tears before using Fig 9 Note elastic bag strap is...

Page 10: ...re to be removed Place door s in a safe location Fig 11 Note bag safety strap and cinch strap Fig 12 There are at least four doorknobs per door 2H unit shown 7 Remove Cinching Strap and Open up Bag ma...

Page 11: ...g on a parallel flat surface and not the floor For a gasket seal housing unlock filter by turning both bolt locking mechanisms counterclockwise with a ratchet This will release the filter from the fla...

Page 12: ...sealing off the housing If tape is used cut in the middle of the taped off section and immediately retape the exposed stubs Fig 18 Top view of both a prefilter and HEPA filter change out sealing lip...

Page 13: ...til it is immobilized and cannot move See Figure 10 16 Pull old bag and stub into the new PVC bag and away from the new filter 17 Slide Filter s into housing and engage locking mechanism to seal off f...

Page 14: ...any bag in bag out contamination system Location specific conditions may prevent the system from operating satisfactorily for certain applications Any non factory alterations to the product may resul...

Page 15: ...old bag stub in the new bag FLUID SEAL METHOD 1 Using the ratchet with the socket remove the two hex nuts and washers for both the top and bottom locking trays 2 Then switch to the 3 8 socket and rem...

Page 16: ...Filter Corporation is committed to continual product development all descriptions specifications and performance data are subject to change without notice Tri Dim products are manufactured to exactin...

Reviews: