19_J05xxx_ SPB 358 E&C.indd 13
9/1/19 5:10 PM
5.
Clock Module Configuration
The interior structure of the device is as shown below:
EN
Clock Module
Transformer
Air Pump
Digital Screen
Test Cabin
K
1
K
2
K
3
5.1
The 4 modes of the clock module
P
1
: To set the daily working period of device.
E.g. The device automatically start working at 7:30 am and shut down at 5 pm
daily (Select the P
1
mode, enter the numeric value of 0730 and 1700 in
turn).
P
2
: To set the pulse signal.
It is not recommended for common users.
Consult the dealers or professionals if needed.
P
3
: To set the date and month on which the device will start to work
and shut down.
E.g. The device automatically start working on 1
st
Oct and shut down on 25
th
Dec (Select P
3
mode, enter the numeric value of 1001 and 1225 in turn).
P
4
: To set the local date and time.
E.g. The SPB 358 device is used in Germany, and the local date & time is 15
th
Jun, 2:15pm (Select P
4
mode, enter the numeric value of 0615 and 1415 in
turn).
13
Caution:
consult the dealers or professionals to open the front cover of the
device to set the timer.