4.4 Installing
ProVent
ProVent 100
The holder (1) and the inlet fitting are integrated
on the housing and are not adjustable.
The lid with the outlet fitting can be turned in 90°
steps (2).
•
Loosen the 4 screws (3) (3 mm Allen screw)
and turn the lid to the desired position
•
Retighten the 4 screws (3).
Tightening torque: 4 Nm.
•
Mount the holder in the vertical position.
Recommended tightening torque for M8
screws: 10 Nm.
•
Ensure sufficient strength of the screw and nut
material.
•
Connect the hoses to the inlet, outlet and oil
return fittings (make sure a sufficient length of
hose is pushed on) and secure with hose
clamps (see Chap.4.2and 4.3).
•
Connect the oil return hose (and non-return
valve if necessary) to the oil sump.
•
To ensure proper functioning, the ProVent
should be protected against dirt (mount splash
guards if necessary).
Fig. 3
Positions of outlet for ProVent 100
ProVent 150
The holder (1) and the inlet fitting are integrated
on the housing and are not adjustable.
The lid with the outlet fitting can be offset in 3°
steps.
ATTENTION
:
not in "Service/Open" position
•
Turn the lid to the desired position.
Do not turn the outlet to the 90°
position (2)
Ensure locking of the retaining
groove!
•
Mount the holder in the vertical position.
Recommended tightening torque for M8
screws: 10 Nm.
Fig. 4
Positions of outlet for ProVent 150
1
2
3
3
Pos. variable
1
2
2