MANN + HUMMEL ProVent
MANN+HUMMEL Industrial Filters
12
ProVent 800
The housing can be turned around the
longitudinal axis before installing it in the
holder.
This enables inlet and outlet fittings to be
adjusted to the installation situation.
•
Loosen the screw (1)
•
Turn the holder (2) into the desired position
and tighten the screw with the nut. Tightening
torque: 9 Nm
•
Mount the holder in the vertical position.
•
Ensure sufficient strength of the screw and
nut material.
•
Connect the hoses to the inlet (3), outlet (4)
and oil return fittings (5) (make sure a
sufficient length of hose is pushed on) and
secure with hose clamps.
•
Connect the oil return hose (and non-return
valve if necessary) to the oil sump.
•
To ensure proper functioning, the ProVent
should be protected against dirt (mount
splash guards if necessary).
Fig. 9
Adjusting holder of ProVent 800
1
2
3
4
5