Assembly
12
MANN+HUMMEL Industrial Filtration
1
4
5
3
13
1
i
7.
Position and fix ‘MAX’ (4) and ‘MIN‘
(5) for maximum and minimum
coolant levels in the coolant
reservoir (1). Ensure that markings
are clearly visible and cannot be
obscured by other fixtures.
The position of markings for
maximum and minimum coolant
levels are fixed by the machine
manufacturer.
8.
Fill and vent the cooling system with
coolant as specified by the unit
manufacturer.
Fill the coolant reservoir (1) up to the
‘MAX‘ mark and close with the
pressure cap (3).
Escape of hot coolant can result in
serious burns.
Ensure that both O-rings (13) are
present on the pressure cap (3) of
the coolant reservoir (1) and that
they are undamaged.
Filling and venting the cooling
system must be carried out in
accordance with the unit
manufacturer’s instructions.
Incorrect filling or venting of the
cooling system may cause the unit
to overheat.
!
CAUTION
NOTICE