Installation Instructions
Section 2
2-6
Part Number 000001774 07/08
Installation Checklist
Before Starting the Ice Machine
All Manitowoc ice machines are factory-operated and
adjusted before shipment. Normally, new installations do
not require any adjustment.
To ensure proper operation, follow the Operational
Checks on page 3-4 of this manual. Starting the ice
machine and completing the Operational Checks are the
responsibilities of the owner/operator.
NOTE: Adjustments and maintenance procedures
outlined in this manual are not covered by the warranty.
Is the ice machine level?
Has all of the internal packing been removed?
Have all of the electrical and water connections
been made?
Has the supply voltage been tested and
checked against the rating on the nameplate?
Is there proper clearance around the ice
machine for air circulation?
Has the ice machine been installed where
ambient temperatures will remain in the range
of 35° – 110°F (1.7° – 43.3°C)?
Has the ice machine been installed where the
incoming water temperature will remain in the
range of 33° – 90°F (0.6° – 32.2°C)?
Are all electrical leads free from contact with
refrigeration lines and moving equipment?
Has the owner/operator been instructed
regarding maintenance and the use of
Manitowoc Cleaner and Sanitizer?
Has the owner/operator completed the warranty
registration card?
Has the ice machine and bin been sanitized?
Has this manual been given to the owner/
operator?
!
Warning
PERSONAL INJURY POTENTIAL
Do not operate equipment that has been misused,
abused, neglected, damaged, or altered/modified
from that of original manufactured specifications.