![Manitowoc QC0700 Service Manual Download Page 90](http://html.mh-extra.com/html/manitowoc/qc0700/qc0700_service-manual_701073090.webp)
Electrical System
Section 6
6-28
Part No. 80-1214-3
QF2300
Initial Start-Up
1B. WATER FILL
After 45 seconds the water float valve
solenoid is energized.
SV2110
RELAY
K1
RELAY
K2
RELAY
K3
RELAY K4
(25)
L1
L2
(54)
(53)
LIQUID LINE
SOLENOID
CENTRIFUGAL
SWITCH
(65)
INTERNAL
OVERLOAD
START
RUN
GEARMOTOR
WATER FLOAT
VALVE
DUMP VALVE
(56)
(55)
(22)
(51)
(52)
7 AMP
FUSE
GROUND
(58)
(57)
EQUALIZATION
SOLENOID
C2
C1
(91)
(22)
1B. Water Fill
(Until Water Contacts Water Level Probe)
Toggle Switch
ICE
Bin Level Probe
Open (No Ice Contact)
Control Board Relays
#1
Liquid Line Solenoid Valve
OFF
#2
Dump Valve
OFF
#3
Gear Motor
ON
#4
Water Float Valve Solenoid Coil
ON
Revised 8/2003