Freeze Cycle
2. FREEZE
The gear motor, compressor,
condenser fan motor and water float
valve solenoid remain energized as
the ice machine makes ice. The
water float valve will open and close
automatically to maintain the proper
water level.
SV3036
RELAY
K1
GROUND
L1
L2 (N)
(21)
(65)
CONTACTOR
COIL
(90)
HIGH
PRESSURE
CUT-OUT
(95)
RELAY
K2
RELAY
K3
RELAY K4
(25)
10 AMP
FUSE
(46)
GEARMOTOR
(47)
GEARMOTOR
RUN CAPACITOR
(48)
(43)
(56)
WATER FLOAT
VALVE COIL
(52)
(22)
(55)
(51)
DUMP VALVE
COIL
FAN MOTOR
(AIR-COOLED ONLY)
(10)
(11)
(14)
(41)
CONTACTOR
CONTACTS
L1
T1
RUN
START
(44)
2. Freeze
(Until Ice Contacts Bin Level Probe for 30 Continuous Seconds)
Toggle Switch
ICE
Bin Level Probe
Open (No Ice Contact)
Control Board Relays
#1
Contactor Coil
Closed / ON
Compressor
ON
Condenser Fan Motor
ON
#2
Dump Valve
OFF
#3
Gear Motor
ON
#4
Water Float Valve Solenoid Coil
ON