3-25
MLC150-1 SERVICE/MAINTENANCE MANUAL
ELECTRICAL SYSTEM
3
Table 3-11. IOLC32 Test Voltages
Pin
Net
Function
Voltages
P1-1
GND
Ground at Remote Battery Negative Terminal
0VDC
P1-2
KL15
Control Module Ignition Power (from engine run switch)
0 VDC Open, 24 VDC Closed
P1-3
ID01
Hydraulic Filter Switch
0 VDC Open, 24 VDC Closed
P1-5
OPH6A18
Drum 1 Free Fall Proportional Solenoid Valve
0 VDC Open, 24 VDC Closed
P1-6
OPH6A19
Drum 2 Free Fall Proportional Solenoid Valve
0 VDC Open, 24 VDC Closed
P1-7
OPH6A20
Open Loop Pump A Control
0 or 24 VDC
P1-8
OPH6A21
Open Loop Pump B Control
0 or 24 VDC
P1-10
CAN_C-H
CAN Bus C - High
N/A
P1-11
8C25 (+UB) Battery Power for Control Module Outputs (from CB25)
24VDC
P1-12
6C1A (+UE) Control Module Battery Power (from K5)
24VDC
P1-13
ID03
Hydraulic Vacuum Switch Open Loop Pump A
2 to 20 mA
P1-14
ID04
Hydraulic Vacuum Switch Open Loop Pump B
2 to 20 mA
P1-15
ID05
Hydraulic Level Switch
0 VDC Open, 24 VDC Closed
P1-17
IDF15
Drum 2 Free Fall Encoder (EU)
P1-19
CAN_C-L
CAN Bus C - Low
N/A
P1-20
8C25 (+UB) Battery Power for Control Module Outputs (from CB25)
24VDC
P1-21
ID07
Remote Control Gantry Cylinder Boom Hoist Sync Switch
P1-22
ID08
Remote Control E-Stop Switch
P1-23
ID09
Remote Control Counterweight Pins Disengage Switch
P1-24
ID10
Remote Control Gantry Cylinder Extend Switch
P1-25
ID11
Remote Control Gantry Cylinder Retract Switch
P1-26
IDF16
Drum 2 Free Fall Encoder (EU)
P1-27
IACV17
Remote Control Drum 4 Pay Out/Haul In Switch
P2-1
ID12
Freon Switch
0 VDC Open, 24 VDC Closed
P2-4
IACV18
ATB Diag
P2-5
ODH3A09
Camera Light
P2-6
ODH3A04
Free Fall System Enable Solenoid
0 VDC Off, 24 VDC On
P2-7
ODH3A07
Swing Encoder
0 or 24 VDC
P2-8
ODH3A10
ECM Key Switch
P2-9
ODH3A12
Freon Switch
P2-10
OPH3A15
Swing Pump A Control
0 or 24 VDC
P2-11
8C26 (+UB) Battery Power for Control Module Outputs (from CB26)
24VDC
P2-12
OS85H
Remote Control Power Switch
P2-13
IACV19
Drum 1 Free Fall Brake Hydraulic PSI
4 to 20 mA
P2-14
IACV20
Drum 2 Free Fall Brake Hydraulic PSI
4 to 20 mA
P2-15
ODH3A01
Alarm: Hydraulic Level, Filter and Vacuum
0 VDC Open, 24 VDC Closed
P2-17
ODH3A09
Camera Lights
P2-16
ODH3A06
Remote Control Power Switch
P2-18
OPH3A14
Swing Pump B Control
0 or 24 VDC
P2-19
OPH3A17
Fan Pump Control
0 or 24 VDC
P2-20
8C26 (+UB) Battery Power for Control Module Outputs (from CB26)
24VDC
REFERENCE
ONLY
Summary of Contents for MLC150-1
Page 1: ...Service Maintenance Manual Manitowoc MLC150 1 R E F E R E N C E O N L Y ...
Page 2: ...R E F E R E N C E O N L Y ...
Page 4: ...THE ORIGINAL LANGUAGE OF THIS PUBLICATION IS ENGLISH R E F E R E N C E O N L Y ...
Page 205: ...R E F E R E N C E O N L Y ...
Page 206: ...R E F E R E N C E O N L Y ...