Installation Instructions
Section 2
6
Part Number 000008463 10/11
4. Assemble LuminIce™ to bracket with three screws
provided. The bulb and bulb wiring must face toward
the rear of the ice machine to allow bulb
replacement with LuminIce™ in place.
5. Mount transformer on evaporator bulkhead above
control box. Attach supplied wire clip and route line
voltage wires through clip.
6. Route line voltage wires (Black & White) through line
voltage Heyco fitting and attach to L1 and L2
contactor terminals.
NOTE: QuietQube models do not have open terminals
on contactor. Remove two wires from contactor, install
supplied electrical connector and connect wires.
Attach With Three Screws
Route Line Voltage Wires Through Clip
Install Transformer
Attach Wire Clip
Route Through Line Voltage Heyco
and
Attach to Contactor Terminals
LuminIce Power
L1
L2
Wires Removed From Contactor
Contactor