Part Number 000008463 Rev 02 3/16
9
LuminIce® Installation Ice Beverage (IB) Single
Evaporator Models
n
Warning
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. Install tubing adapters into bulkhead:
• Remove dust cover from top of evaporator to expose
space between the evaporator and bulkhead.
• Remove and discard plastic caps to allow installation
of tubing adapters.
• Install the longer tubing adapter in the upper
evaporator compartment bulkhead location.
• Install the shorter tubing adapter in the lower
evaporator compartment bulkhead location.
3. Mount the LuminIce® and transformer to the mounting
bracket.
• Mount the components on the opposite side of the
bracket lip. The bracket lip will slide between the top
rail and insulation when mounted.
• LuminIce® - The bulb and bulb wiring must face up
to allow bulb replacement with the LuminIce® in
place. Mount the LuminIce® on the left side of the
bracket.
• Transformer - Mount the transformer to the right of
the LuminIce®.
4. Install mounting plate in ice machine and secure with
fasteners. The mounting plate has pass-through holes
for the hose adapters.
5. Route transformer line voltage wires (black and white)
along the evaporator bulkhead and through the line
voltage Heyco fitting. Disconnect L1 and N wires and
install L1 and N of wiring adapter to the incoming
power supply wires. Connect removed wires and
LuminIce® wires to adapter. Bundle and secure any
excess line voltage wire near the transformer.
Section 2
Installation
Ice Machine Power
LuminIce® Power
Incoming Power Supply
N