Part Number 000008463 Rev 02 3/16
21
Replacement Bulb Usage
Replacement bulbs are not interchangeable between
LuminIce® and LuminIce® II.
• LuminIce® replacement bulb - K00425
• LuminIce® II replacement bulb - K00454
LUMINICE® II INDICATOR LIGHTS
LuminIce® II has an LED light for status indication:
• Steady red light = Replace bulb
• Flashing red light = Service is required
• Blue = Normal operation
• Red/Blue flash = Incorrect replacement bulb has been
installed.
Bulb Replacement Frequency
LuminIce® and LuminIce® II bulbs require replacement
on a yearly basis. Although the bulb will still illuminate
after 12 months, the effectiveness of the bulb diminishes
as operational hours increase. To retain maximum
effectiveness, replace the bulb on a 12 month schedule.
LuminIce® II has an indicator light that will illuminate
red when the bulb needs replacement. A remote LED is
available as an accessory (K00455) to allow all indicators
(including the reminder) to be viewed without removing
the ice machine panels.
LuminIce® Reminder Setup for Indigo Model
Ice Machines
Perform the procedure below to display a change-
bulb reminder every 12 months. Complete display
panel navigation is available in the Indigo® ice machine
Installation, Operation and Maintenance Manual.
Publications for all Manitowoc equipment are available on
our website www.manitowocice.com.
1. From the Set-Up menu, use the Down arrow to
highlight LuminIce®.
2. Press the Checkmark. On this screen, you can choose to
turn the reminder to AUTO or OFF by highlighting your
choice and pressing the Checkmark. Selecting one will
deselect the other.
3. When the check reflects your preference, use the Down
arrow to navigate to Exit and press the Checkmark. The
display will return to the Set-Up menu.
Bulb Replacement
n
Warning
Disconnect power to ice machine at the electrical
disconnect. Pressing the power button does not
disconnect line voltage.
1. Disconnect all power to the ice machine at the
electrical disconnect.
2. Open the front door of the ice machine and then
remove the top panel.
3. Disconnect the power connector from the LuminIce®
bulb.
4. Push bulb with finger and pull with other hand toward
the rear of the ice machine until bulb is free.