26
Part Number 000014141 Rev 08 5/21
Installation
Section 2
Remote Condenser Models
Ice
Machine
Remote
Condenser
Additional Amount
of Refrigerant
to Be Added to
Nameplate Charge
for 50' to 100'
(15 to 30 Meter)
Line Sets
IF0500N
JCF0500
1.5 lbs - 680 g
IT0500N
JCT0500
1.5 lbs - 680 g
IF0600N
JCF0900
1.5 lbs - 680 g
IF0900N
JCF0900
2 lbs - 907 g
IT1200N
JCT1200
2 lbs - 907 g
IT1500N
JCT1500
2 lbs - 907 g
IT1900N
JCT1500
2 lbs - 907 g
Line Set
Discharge
Line
Liquid
Line
Model
RT
20/35/50
R404A
1/2 inch
(13 mm)
5/16 inch
(7.9 mm)
IF0500N
IF0600N
IF0900N
RT
20/35/50
R410A
1/2 inch
(13 mm)
5/16 inch
(7.9 mm)
IT0500N
IT1200N
RL
20/35/50
R410A
1/2 inch
(13 mm)
3/8 inch
(9.5 mm)
IT1500N
IT1900N
NOTE: R404A line sets have white
protective caps and R410A line sets have
pink protective caps.
n
Warning
Potential Personal Injury Situation
The ice machine head section contains
the refrigerant charge. Installation and
brazing of the line sets must be performed
by a properly trained and EPA certified
refrigeration technician aware of the
dangers of dealing with refrigerant charged
equipment.
CALCULATING INSTALLATION DISTANCES
Line Set Length
The maximum tubing length is 100 feet (30
meters).
Line Set Rise/Drop
The maximum rise is 35 feet (10.7 meters).
The maximum drop is 15 feet (4.5 meters).
Notice
If a line set has a rise followed by a drop,
another rise cannot be made. Likewise,
if a line set has a drop followed by a rise,
another drop cannot be made.
Calculated Line Set Distance
The maximum calculated distance is 150
feet (45 meters).
Line set rises, drops, horizontal runs (or
combinations of these) in excess of the
stated maximums will exceed compressor
start-up and design limits. This will cause
poor oil return to the compressor. Make the
following calculations to make sure the line
set layout is within specifications.
1.
Insert the
measured rise
into the
formula below. Multiply by 1.7 to get
the
calculated rise
.
2.
Insert the
measured drop
into the
formula below. Multiply by 6.6 to get
the
calculated drop
.
3.
Insert the
measured horizontal
distance
into the formula below. No
calculation is necessary.
Summary of Contents for Indigo NXT
Page 2: ......
Page 8: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 50: ...50 Part Number 000014141 Rev 08 5 21 Maintenance Section 4 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 55: ......
Page 56: ......
Page 57: ......