Clean and sanitize ice machine 

(continued)

 

 

©McDonald’s Corporation · Planned Maintenance Manual · Revised February 2019 

Page 2 of 4

 

M

an

itow

oc

 Ice

 M

ac

hin

e M
od

els

 In

digo

®

NX

T

 

M

onthl

BE

 1

3 M

 

Prepare DeLimer solution. 

Follow label instructions to 

prepare the correct amount of 

delimer. 

 

For models: 

IF300, IT420, IT520, IT620

 

Kay Delimer - Mix 2 packets 

with 1 liter of warm water 

or 

McD KL - Measure 120 ml 

 

IT1200, IF1400, IT1500, 

IF1800C, IT1900, IF2100C

 

Kay Delimer - Mix 5 packets 

with 1 liter of warm water 

or 

McD KL - Measure 290 ml 

 

For all other models

 

Kay Delimer - Mix 4 packets 

with 1 liter of water  

or 

McD KL - Measure 200 ml 

 

*Amounts vary by ice machine size 

due to amount of water being held in 

the water trough of each machine.  

Larger machines hold more water.  

Concentration should remain the 

same.  

 

 

DeLimer  

 

 

 

 

 

 

 

 

 

Press CLEAN switch. 

Push the clean button then 

select “Turn off when  

complete” to start the  

cleaning process. 
 
 

 

Delime evaporator and water 

circulation system. 

Wait for approximately 3 

minutes until “Please add 

chemicals and confirm” is 

displayed, then pour the pre-

mixed solution into the water 

trough and press “Chemicals 

added”.  

 

 

Allow clean cycle to run. 

The ice machine will auto-

matically run through a wash 

cycle and several rinse cycles. 

The entire cycle lasts  

approximately 30 minutes.  

 

 

 

 

Turn off power to the ice 

machine.  

 

Do not begin cleaning other 

parts of the ice machine until 

it is unplugged or  

breaker/disconnect is turned 

off. 

 

 

Remove water curtain.  

Gently flex the curtain in the 

center and remove it from the 

right side.  Slide the left pin 

out.

 

 

 

10 

Remove the ice thickness 

probe.  

Compress the hinge pin on 

the top of the ice thickness 

probe.  

 

Pivot the ice thickness probe 

to disengage one pin then the 

other. The ice thickness probe 

can be cleaned at this point 

without complete removal. If 

complete removal is desired, 

disconnect the ice thickness 

control wiring from the  

control board.  

 

 

Summary of Contents for IF300

Page 1: ...t clean towels Bucket soiled towels Ice scoop McD KL Delimer McD DR Sanitizer Multi Surface Glass Cleaner Screwdriver Phillips Kay Delimer Kay 5 Sanitizer Procedure 1 Remove front panel Use a Phillips screwdriver to loosen the two screws secur ing the door Do not remove screws completely they are secured to prevent loss 2 Turn ice machine off After ice has fallen from the evaporator turn the machi...

Page 2: ...elect Turn off when complete to start the cleaning process 6 Delime evaporator and water circulation system Wait for approximately 3 minutes until Please add chemicals and confirm is displayed then pour the pre mixed solution into the water trough and press Chemicals added 7 Allow clean cycle to run The ice machine will auto matically run through a wash cycle and several rinse cycles The entire cy...

Page 3: ...evel probe Pull the water level probe straight down to disengage Lower the water level probe until the wiring connector is visible Disconnect the wire lead from the water level probe Remove the water level probe from the ice machine 15 DeLime plastic parts Mix the correct amount of delimer with 4 gallons 15 liters of warm water in a three compartment sink Kay Delimer 4 packets or McD KL 150 ml Pla...

Page 4: ... 5 Mix 2 packets with 1 liter of water McD DR Measure 40 ml Amounts vary by ice machine size due to amount of water being held in the water troughs of each machine Larger machines hold more water Concentration should remain the same Sanitizer 22 Press CLEAN switch Push the clean button then select Turn on when complete sanitize cycle Check box to return to ON start ice making at the completion of ...

Reviews: