HYDRAULIC SYSTEM
GRT9165 SERVICE MANUAL
2-44
Published 10-01-2020 Control # 699-00
FIGURE 2-17
2
11
12
13
5
6
3
4
16
17
15
19
23
22
25
1021
10122
10
8
21
18
20
7
Swing Directional Control Manifold Valve
1
Solenoid Valve - Swing Enable
2
Tank Port — T
3
Inlet Port — P1
4
Gauge Port — GP5
5
Solenoid Valve - Left Swing
6
Solenoid Valve - Right Swing
7
Pressure Transducer
8
Gauge Port — GP4
9
Orifice - 0.020 in
10
Drain Port — D3
11
Gauge Port — GP2
12
Drain Port — D2
13
Work Port — MB — Left Swing
14
Pressure Compensating Valve
15
Gauge Port — GP3
16
Work Port — MA — Right Swing
17
Shuttle Valve
18
Drain Port — D5
19
Drain Port — D1
20
Drain Port — D6
21
Gauge Port — GP1
22
Drain Port — D7
23
Drain Port — D4
24
Accumulator Port — ACC1
25
Accumulator Port — ACC2
1
14
9
24
Bottom View
Front View
Forward
Forward