![Manitowoc Grove GRT9165 Service Manual Download Page 276](http://html.mh-extra.com/html/manitowoc/grove-grt9165/grove-grt9165_service-manual_701207276.webp)
MAINTENANCE AND LUBRICATION
GRT9165 SERVICE MANUAL
9-32
Published 10-01-2020 Control # 699-00
Item
Lube Point
Description
Figure No.
Approved
Lubricant
Approximate
Capacity
Service Interval
Service
Application
Lift Cylinder Lubrication
39a
Lower Lift
Cylinder Pivot Pin
L
Until grease
extrudes
Every 100 hours, or
1 month, whichever
interval comes first
LUBRICATE
1 grease fitting,
1 service point
39b
Lower Lift
Cylinder Pivot Pin
L
Until grease
extrudes
Every 100 hours, or
1 month, whichever
interval comes first
LUBRICATE
1 grease fitting,
1 service point
NOTE 43: DO NOT USE
non semi-synthetic lubricant
. Use of non-approved lubricant may damage components.
NOTE 44:
Before operating crane in cold weather (arctic) ambient temperatures below -9°C (+15°F), Standard grease
must be fully purged and replaced with Cold Weather grease meeting Grove U.S. L.L.C. specifications as
shown in Table 9-4
: Approved Lubricant Reference Table
, page 9-8 in this
Operator Manual
. See also your
GRT9165
Service Manual
for specified maintenance and lubrication instructions.
CAUTION
Possible Equipment Damage!
Use semi-synthetic or synthetic lubricants as listed in Section 6 of the
Operator Manual
. See
also
, page 8-1 for maintenance and lubrication instructions. Use of non-
approved, non semi-synthetic lubricant may damage components and/or invalidate
published lubricant intervals. Failure to follow this instruction may cause damage to
equipment