KEEP cables away from objects such as heating and air conditioning
ducts, metal construction plates, and anything else with sharp
edges that can damage the cables.
Cautions: Room Station Rough-In
Careful consideration should be used when determining the location of
the room stations and master. Since this is a retrofit system you will
not be able to control the location of the existing system. But please
follow the guidelines below if you install any new locations:
•
DO NOT
install room stations in return air ducts.
•
DO NOT
install room stations in exterior walls. Insulation materials
will change speaker range and efficiency. Temperature changes in
the wall will reduce speaker life.
•
DO NOT
install room stations in saunas. They will not withstand the
extreme heat and moisture.
•
DO NOT
install room stations underneath cabinets or over counter
tops.
•
DO NOT
install room stations in stud cavities with other wiring or
appliances.
•
DO NOT
install room stations within 18” of dimmers, fluorescent
light fixtures, security wiring, cordless phone units, and other
control wiring.
•
DO NOT
install room stations within 10 feet of other room stations
or the dmc3-4 master unit. This will cause acoustic feedback.
•
DO NOT
install room stations in stud cavities with other room
stations or the dmc3-4 master unit. This will cause acoustic
feedback.
•
DO NOT
install room stations facing other room stations or the
dmc3-4 master unit. This will cause acoustic feedback.
•
DO
make sure all mounting rings are level and oriented as shown in
these instructions.