4.1 Assembly
The unit is supplied with a standard line cord, however an electrical plug rated for the correct electrical service
must be installed by a licensed electrician.
4.1.1 Quartz Heating Elements
Avoid Heating Element Damage
Oily or foreign substances will damage the heating element. In case of contact, wipe the surface with Isopropyl
Alcohol. Always wear lint-free gloves when handling the heating element.
WARNING:
Never operate the unit when placed on its side. In this position, the Quartz
Heating Element filaments (1) compress and arcing results in premature failure of the element filament.
Always operate the unit with the Quartz Heating Elements in the horizontal (normal operating) position.
1.
The Quartz Heating Element has a female electrical connector at both ends (1). Hold the Quartz
Heating Element near both ends and push the female electrical connector onto the spring socket (2).
2.
Place the opposite end of the Quartz Heating Element on the spring socket (1) on the other side of the
Reflector Assembly. Allow the spring loaded pressure to hold it in position.
3.
Install the remaining Quartz Heating Elements as described in the previous steps.