![m&h Inprocess 40.01-TX Operating Instructions Manual Download Page 9](http://html1.mh-extra.com/html/mandh-inprocess/40-01-tx/40-01-tx_operating-instructions-manual_3073614009.webp)
Infrared Probe 40.01-TX/RX
8
up
down
±5° down
up
Probe with other shanks
Available Shanks: L: Order
Number:
D20-D8-L25-B 65
(2.56”)
40.01-D8-L25
D20-D32-L100-B 62
(2.44”)
40.01-D32-L100
NIKKEN-NC5-46 115,5
(4.55”)
40.01-NC5-46
NIKKEN-NC5-63 115,5
(4.55”)
40.01-NC5-63
D20-Erowa-ITS 91
(3.58”)
40.01-ITS
Probe with shank THERMO-LOCK
®
(patented)
Available Shanks: L: Order
Number:
DIN69893 HSK-E32
86 (3.39”)
40.01-HSK32E-TI
DIN69893 HSK-E40
86 (3.39”)
40.01-HSK40E-TI
DIN69893 HSK-E50
92 (3.62”)
40.01-HSK50E-TI
DIN69893 HSK-A63
92 (3.62”)
40.01-HSK63A-TI
Patented THERMO-LOCK
®
Technology prevents thermal
expansion of the HSK and heat transfer from the spindle to the
probe. This ensures that the probe delivers stable, precise results
even by large temperature differences between the spindle and
the HSK.
Aligning probe in shank with 90°Adapter
Procedure:
e
Loosen adjustment screws „A“ (4x) then tighten lightly.
e
Loosen clamping screws „C“ (2x) then tighten lightly.
e
Adjust the angular position of the probe using cylinder screw AF4mm to (±5°).
e
Tighten the clamping screws „C“ (2x).
e
Alternately tighten the adjustment screws „A“ (4x).
e
Calibrate probe.
Hexagon key AF4mm
#3489
Not included
Not
included
Air Nozzle with rotary joint
for tool holder VDI
91.00-SWV
90° Adapter for
Tool Holder VDI
D20-VDI-90°