Infrared Probe 40.01-TX/RX

Probe with shank SK 

 
Available Shanks: L: Order 

Number: 

DIN69871-SK30 94,5 

(3.72”) 

40.01-SK30 

DIN69871-SK30-Mube 94,5 

(3.72”) 

40.01-SK30-Mube 

DIN69871-SK40 96,5 

(3.8”) 

40.01-SK40 

DIN69871-SK40-70 120 

(4.72”) 

40.01-SK40-120 

DIN69871-SK50 96,5 

(3.8”) 

40.01-SK50 

DIN69871-SK60 116,5 

(4.59”) 

40.01-SK60 

BT30 77 

(3.03”) 

40.01-BT30 

BT30 94,5 

(3.72”) 

40.01-BT30-94,5 

BT30 127 

(5”) 

40.01-BT30-127 

BT30 152 

(5.98”) 

40.01-BT30-152 

BT30 177 

(6.97”) 

40.01-BT30-177 

BT40 96,5 

(3.8”) 

40.01-BT40 

BT40-70 120 

(4.72”) 

40.01-BT40-120 

BT50 111,5 

(4.39”) 

40.01-BT50 

CAT40 96,5 

(3.8”) 

40.01-AN40 

CAT40-70 120 

(4.72”) 

40.01-AN40-120 

CAT50 96,5 

(3.8”) 

40.01-AN50 

Other shanks upon request 

 

Probe with shank Coromant Capto 

 
 
 

Available Shanks: L: Order 

Number: 

Coromant Capto C4 

86 (3.39”) 

40.01-C4 

Coromant Capto C5 

86 (3.39”) 

40.01-C5 

Coromant Capto C5 

121,5 (4.78”)  40.01-C5-121,5 

Coromant Capto C5-90°  102,5 (4”) 

40.01-C5-90° 

Coromant Capto C6 

92 (3.62”)) 

40.01-C6 

Coromant Capto C6 

121,5 (4.78”)  40.01-C6-121,5 

Coromant Capto C6-90°  102,5 (4”) 

40.01-C6-90° 

Coromant Capto C8 

92 (3.62”) 

40.01-C8 

Coromant Capto C8 

121,5 (4.78”)  40.01-C8-121,5 

Coromant Capto C8-90°  102,5 (4”) 

40.01-C8-90° 

Other shanks upon request 
 
 
 

Probe with tool holder VDI 

Available Tool holders: L: Order 

Number: 

VDI 16 

75,0 (2.95”)  40.01-VDI16 

VDI 16-90° 

56,0 (2.2”) 

40.01-VDI16-90° 

VDI 20 

75,0 (2.95”)  40.01-VDI20 

VDI 20-90° 

56,0 (2.2”) 

40.01-VDI20-90° 

VDI 25 

75,0 (2.95”)  40.01-VDI25 

VDI 25-90° 

56,0 (2.2”) 

40.01-VDI25-90° 

VDI 30 

79,0 (3.11”)  40.01-VDI30 

VDI 30-90° 

60,0 (2.36”)  40.01-VDI30-90° 

VDI 40 

98,5 (3.38”)  40.01-VDI40 

VDI 40-90° 

79,5 (3.13”)  40.01-VDI40-90° 

VDI 50 

98,5 (3.38”)  40.01-VDI50 

VDI 50-90° 

79,5 (3.13”)  40.01-VDI50-90° 

VDI 60 

98,5 (3.38”)  40.01-VDI60 

VDI 60-90° 

79,5 (3.13”)  40.01-VDI60-90° 

VDI 80 

98,5 (3.38”)  40.01-VDI80 

VDI 80-90° 

79,5 (3.13”)  40.01-VDI80-90° 

Other tool holders upon request 

Not  
included 

Not 
included 

Not included 

91.00-SWV 
not 
included 

Summary of Contents for 40.01-TX

Page 1: ...chnical Data Dimensions 1 Probe ON OFF Angle Transmitting Receiving 2 Stylus Change Battery Replacement Optical Status Display 3 Aligning Stylus to Spindle Centre 4 Infrared Signal Range Power Off Del...

Page 2: ...dby 12 months Alternative 1x3 6V Battery Power Supply Type AA IEC Material Stainless steel Weight without Shank ca 390g Temperature Operating 10 50 C Storage 5 70 C Repeatability max 2Sigma 1 m with 5...

Page 3: ...tting Receiving Receiving Transmitting Receiving Transmitting Infrared Probe 40 01 TX RX Adjustable Range 1 6m 5 2 3 3m 10 8 4 0m 13 1 Infrared Receiver 91 40 RX TX C ON Off Range 4 0m 13 1 alternativ...

Page 4: ...y cover with bayonet lock to open and close e When closing the battery compartment check the O Ring for any damage e Replace empty battery immediately Optical Status Display LED blinking green e Probe...

Page 5: ...dicator reading Loosen the A screws that were used 1 turn Repeat procedure until runout is 20 4 Adjustment to 2 Turn the probe until the maximum deviation is shown on the indicator Turn the A screws h...

Page 6: ...aning the workpiece and the stylus tip To clean with through spindle air e Remove service cover with eyelid and conical spring by hand e Clean probe and parts under flowing water e Replace parts and c...

Page 7: ...HSK A50 86 3 39 40 01 HSK50A DIN69893 HSK A50 116 5 4 59 40 01 HSK50A 116 5 DIN69893 HSK E50 92 3 62 40 01 HSK50E DIN69893 HSK E50 116 5 4 59 40 01 HSK50E 116 5 DIN69893 HSK F50 92 3 62 40 01 HSK50F D...

Page 8: ...5 4 78 40 01 C5 121 5 Coromant Capto C5 90 102 5 4 40 01 C5 90 Coromant Capto C6 92 3 62 40 01 C6 Coromant Capto C6 121 5 4 78 40 01 C6 121 5 Coromant Capto C6 90 102 5 4 40 01 C6 90 Coromant Capto C8...

Page 9: ...ed THERMO LOCK Technology prevents thermal expansion of the HSK and heat transfer from the spindle to the probe This ensures that the probe delivers stable precise results even by large temperature di...

Page 10: ...00 T20 2 HM M4 Tungsten carbide shaft 91 00 T20 3 HM M4 Tungsten carbide shaft 91 00 T20 4 HM M4 Tungsten carbide shaft 91 00 T20 5 ST M4 Steel shaft 91 00 T20 6 ST M4 Steel shaft 91 00 T20 7 ST M4 St...

Page 11: ...on for battery cover 1351 Clamping screw AF2 5mm 1352 Adjustment screw DIN913 M4x8 AF2mm 3240 Service cover 3455 O Ring 16x1 Viton for service cover 2906 Metal eyelid 2931 Conical spring 3239 O Ring 1...

Page 12: ...ories Accessories Order Number Description 40 01 TB Toolbox 1x Mounting Pin 0885 2x Hexagon key AF2mm 1097 1x Hexagon key AF2 5mm 1346 91 00 SWV Air Nozzle with rotary joint for VDI shanks D20 VDI 90...

Reviews: