![M&G DuraVent DuraStack PRO DAS1 Installation And Maintenance Instructions Manual Download Page 9](http://html.mh-extra.com/html/mandg/duravent-durastack-pro-das1/duravent-durastack-pro-das1_installation-and-maintenance-instructions-manual_682456009.webp)
Flue
Diameter Ø
(in)
Number of tube
per Joint
5 to 10
1/5
11 to 16
1/4
18 to 22
1/3
24 to 28
1/2
30 to 36
2/3
32 to 36
3/4
TABLE 6 -
Expected number of
Tubes per Joint Assembly
(for S-2000, S-650 or S-375)
SEALANT USAGE
1.
Part No. S-2000:
a high temperature pre-mixed sealant for flue gas temperature up
to 2000°F. S-2000 IS WATER SOLUBLE AND SHOULD NOT BE USED WHERE EXPOSED
TO WEATHER
2.
Part No. S-650
(Permatex® Red High Temp Silicone) is red and is one of
our UL approved sealants for temperatures up to 650°F. Can also be used for
weathering/sealing on outdoor seams & Channel Bands where necessary.
3.
Part No. S-375
(Nuflex 302 General Purpose) is a low temperature grey silicone
(450°F) only for weathering/sealing on outdoor seams & Outer Band BSE where necessary.
CAUTION:
- THE OUTER BAND
(BSE)
IS DESIGNED TO SLIDE ON THE OUTER WALL. DO NOT
ATTACH BY SCREWS INTO THE OUTER CASING.
- DO NOT ALLOW SCREWS TO PENETRATE THE INNER PIPE. THIS CAN CAUSE
CORROSION, GAS LEAKAGE OR EXPANSION FAILURE.
- NEVER USE SCREWS THROUGH THE OUTER JACKET OF A BELLOW LENGTH
9
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 11 - Joint Assembly Step 6
STEP 6 (DIS PRO and DAS PRO only)
Secure the Outer Casing with the Outer Band (
BSE
).
Joint installation is now complete.
NOTE:
Seal the
BSE
band with
S-375