12
SP2500-H | 1.00.02
www.mc-techgroup.com
8
TECHNICAL DATA
Technical data SP
®
series
SP2500-H
SP2500-H/C/I/BB SP2500-H/C/I/BB/F
Part No.
20S3510
20S3520
20S3530
Integrated backpurging
No
Via filter space
Via filter element
Weatherproof cover
Yes
Electrical connection
Terminals; max. 4 mm², 2 x PG13.5 cable gland
Degree of protection of terminal
box
IP 54 EN 60529
Power supply
230 V 50/60 Hz, 800 W or 115 V 60 Hz, 800 W (fuse 10 A)
Material of medium contacted parts Stainless steel 316Ti, 316L, FKM*, Graphite**
Ambient temperature -20 to +60 °C*** /PT100, /Fe-CuNi,/Ni-CrNi** = -20 to +80 °C
Operating temperature
0 - 180°C* /PT100** /Fe-CuNi** /Ni-CrNi**
Process pressure
0.4 to 6 bar abs.
Ready for operation
After 40 min
Alarm contact rating
250 V 3 A~, 0.25 A=, operating point: ΔT 30 °C** to T
nominal
Sample gas outlet connection
1/4"-NPT* internal, for tube connection Ø 6, 8 or 10 mm**
Calibration gas backpurging
connection
1/4“ NPT i*/C**
Back purging: tube 8 mm, calibration gas:
tube 6 mm
Isolating valve/I connection
1/8“ NPT i
Control air pressure range
3 – 10 bar
Filter space volume
280 cm
3
Filter fineness
S-2K150= ceramic*, 2µm, /F-0,1GF150= glass fiber**, 0.1µm,
/FW= glass fiber/spun glass**
Mounting flange
DN 65 PN 6, Form B, 1.4571* >DN or ANSI possible**
Weight
Approx. 17 kg*
Electrical equipment standard
EN 61010, EN 60519-1
* Standard
** Optional
*** At high ambient temperatures, the PT100 (Part No. 20S9025) or thermocouple Fe-CuNi or Ni-CrNi (Art. No.
20S9027 or 20S9028) option should be selected instead of the thermostat. The use of an additional electronic
thermostat is necessary (see also data sheet 4.3).