background image

Rolling Code Transmitters - Series "100"

Rolling Code Transmitters - Series "100"

Specifications and Programming Instructions

Specifications and Programming Instructions

Commercial Sequence or SBC Programming (Optional)

Modes

Functions

Programming (on operator's ECB)

Commercial 
Sequence - 
1-Button

OPEN / CLOSE → Button

Door is CLOSED: 

- Click Button → Door OPENS FULLY

During UPWARD Travel:

- Click Button → Nothing happens

Door is OPENED:

 

- Click Button → Door CLOSES FULLY

During DOWNWARD Travel:

- Click Button → Door reverses and OPENS FULLY

Door is STOPPED:

- Not possible in this mode. Door is either FULLY 
OPENED or FULLY CLOSED.

Standard default mode.

1.Door is in fully CLOSED position.
2.On ECB, verify if the close limit 

switch is activated (CLOSE LED is 
ON).

3.On ECB, set selector switch on 

9 = SBC

.

4.On ECB, press “

STOP

” button.

5.On ECB, select run mode 

(1, 4, or 5)

.

Single Button 
Control (SBC)

Available with the 
Electronic Control 
Board (ECB) only.

Alternating 
Sequence

OPEN / STOP / CLOSE → Button

Door is CLOSED:

- Click Button → Door OPENS

During UPWARD Travel:

- Click Button → Door STOPS

Door is STOPPED:

- Click Button → Door CLOSES

During DOWNWARD Travel:

- Click Button → Door STOPS

Door is STOPPED:

- Click Button → Door OPENS

Note

: If the door is STOPPED for more than 2 minutes,

the next movement will be UPWARD regardless of the 
previous movement.

1.Door is in fully CLOSED position.
2.On ECB, verify if the close limit 

switch is activated (CLOSE LED is 
ON).

3.On ECB, set selector switch on 

9 = SBC

.

4.On ECB, press “

OPEN

” button.

5.On ECB, select run mode 

(1, 4, or 5)

.

FCC and ISED

This device complies with Part 15 of the FCC Rules and  Innovation, Science and Economic Development Canada’s licence-exempt RSS(s).
Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2)  This device must accept any
interference received, including interference that may cause undesired operation. 

WARNING:

 Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user’s authority

to operate the equipment. 

NOTE: 

This device has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules and

Industry   Canada  ICES  standards.  These  limits  are  designed  to  provide  reasonable  protection  against  harmful  interference  in a  residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: (1) Reorient or relocate
the receiving antenna. (2) Increase the separation between the equipment and receiver. (3) Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected. (4) Consult the dealer or an experienced radio/TV technician for help.

For   further   information,   please   consult   the   operator's   Installation   &   Instruction   Manual   or   contact   our   Technical
Support Department at 

1-800-361-2260

.

1-800-361-2260

www.manaras.com

4

TN1054 REV 2 - 2022/01/24

Reviews: