EN
3
Remote control
3
1
3
2
1 Switching on and off (
ON / OFF
)
2 Blower speed control
3 Temperature control
Note
To reduce power consumption, 24 hours after
the last shutdown, the Cooltronic G2.5 Hatch
activates standby current mode automatically.
This reduces the power demand of the system
to a minimum.
Please note:
After activation of standby current
mode the system can only be switched on via
the control unit.
3.1 Starting up the remote control
With the airconditioning system switched off,
press the button of the control unit and keep
it pressed until
appears flashing on the dis
play. As soon as
is no longer flashing, press
the
ON / OFF
button of the remote control within
30 sec. The required activation is confirmed
with an acoustic signal. If the time is exceeded
repeat the process.
3.2 Shutting down the remote control
Keep the button of the control unit pressed
until
flashes on the display. As soon as
is no longer flashing, press the button within
30 sec. If the time is exceeded repeat the
process.
3.3 Manual operation
3.3.1 Setting the temperature and blower
speed with the remote control
Set a temperature value between 15 ºC and
27 ºC or 59 ºF and 71 ºF by briefly pressing the
or button. The set temperature value
appears in the display.
Set a blower speed V1, V2, V3, V4 or V5 by keep
ing the button pressed.
During the setting the blower level is shown in
the display.
3.4 Automatic operation
3.4.1 Setting the temperature with the
remote control
Set a temperature value between 15 ºC and
27 ºC or 59 ºF and 71 ºF by briefly pressing the
or button. The set temperature value and
CA
(automatic operation) are shown alternately
in the display.
3.4.2 Deactivate function F4 ( automatic
operation) with the remote control
Press the button. The airconditioning system
switches from Function
F4
to Function
F0
(man
ual operation).
Operating Instructions | Cooltronic G2.5 Hatch