background image

6

POWER REQUIREMENTS

The fridge/freezer is designed to operate on AC or 
DC voltage.

 

AC input 240V AC at 50Hz (e.g. electrical  

  power point)

 

DC input 12V or 24V DC (e.g. car cigarette lighter  

  or car battery)

 

The power supply automatically switches the  

  fridge/freezer to mains operation when  
  connected to 240V mains power, even if  
  the 12V/24V DC power cable is connected.

 

If the fridge/freeze is operating when the vehicle  

  ignition is switched OFF, the fridge/freezer will  
  switch OFF automatically when the power  
  source voltage falls below the Battery Monitor  
  cut-out setting.

 

The fridge/freezer will automatically switch  

  back ON when the vehicle is re-started and  
  the power source voltage reaches the Battery  
  Monitor cut-in setting.

OPERATING YOUR FRIDGE/FREEZER WITH  
12/24V DC

 

Plug the 12V/24V DC power cable into the DC  

  power socket (as circled) on the end of the  
  fridge/freezer and then connect to the vehicle  
  cigarette lighter socket or suitable 12V or 24V  
  DC power source.

 

The fridge/freezer will automatically turn on, there  

  is no requirement to switch the appliance on.

 

The display will automatically show the current  

  internal cabinet temperature.

 

For optimum performance and efficiency, it is  

  important that the fridge/freezer has a reliable  
  DC power source available. Direct connection to  
  the battery is recommended and reduces the  
  risk of voltage dropping to the appliance.

 

Use only the 1.5m DC power cable supplied with  

  the fridge/freezer.

Important:

 If a DC extension cable is required 

we recommended use of a 6mm dia. (AWG11) 
4.58mm

2

 Twin Sheath Two Core cable with direct 

connection to the positive and negative battery 
terminals with 15A inline fuse protection.

 

The fridge/freezer is equipped with an electronic  

  control system that will prevent polarity reversal.  
  In the event that the battery connection is  
  reversed the unit will not start or operate. The  
  power input socket is fitted with a 15A blade  
  fuse for protection.

12/24V DC POWER REQUIREMENTS 

If your fridge/freezer is cutting out prematurely, it 
could be due to:

1.

 

The low voltage protection being set too high on  

  the Battery Monitor

2.

 

DC power cable and/or connections are not  

  suitable to carry the required current. Check the  
  power cable and all connections and adjust the  
  Battery Monitor on the control panel.

 

The fridge/freezer is equipped with a multi-level 

  Battery Monitor that protects your vehicle battery  
  against excessive discharging when the fridge/ 
  freezer is connected to 12V or 24V DC power  
 source.

Important:

 When using the fridge/freezer with DC 

power supply, we recommended setting the Battery 
Monitor to LOW (L).

Note:

 A battery charger may only be connected 

to the battery when the fridge/freezer has been 
disconnected from the DC power source.

 

Over-voltage may cause damage to the electronics  

  of the fridge/freezer.

 

Your fridge/freezer is equipped with reverse  

  polarity protection. It protects your fridge/ 
  freezer against reverse battery connection  
  and short circuit.

Summary of Contents for COMP02034

Page 1: ...IMPORTANT Read instructions before operation Owners Manual FRIDGE FREEZERS COMP02034 45L Cold Zone COMP02045 60L Cold Zone COMP02056 72L Flexi Zone COMP02067 82L Cold Zone SAA 140988 EA ...

Page 2: ...fridge freezer 12 24V DC 7 Operating your fridge freezer 240V AC 8 Temperature control 9 Bluetooth connection instructions 10 Cold Zone operation 11 Flexi Zone operation 12 Battery monitor setting 13 Using with solar panel or generator 14 Tips and suggestions 14 Maintenance and service 15 Troubleshooting 16 Specifications ...

Page 3: ...faces Note Installation of AC power in boats should be carried out by a qualified electrician Protect the power cable Do not kink or damage the power cable Do not wrap it around the appliance Do not pull the unit by the cable Do not use the cable as a handle close a door on the cable or pull the cable around sharp edges or corners Keep the cable away from heated surfaces Never touch uninsulated ca...

Page 4: ...Y AND PARTS 1 Lid Handle 2 Control Panel 3 Carry Handles 4 Power Input Panel 5 12V 24V DC Power Cable 6 240V AC Power Cable 7 Storage Baskets 8 Internal Light 9 Air Flow Vent COMP02067 shown 6 5 4 9 3 7 8 1 2 3 ...

Page 5: ...dge or a freezer or both simultaneously The fridge freezer may be used for outdoor use such as for camping purposes If you wish to refrigerate medicines first check to ensure the fridge freezer s cooling capacity meets the demands of the respective medicines The fridge freezer is designed to operate in ambient temperatures between 10 and 55 C in a maximum air humidity of 90 The fridge freezer can ...

Page 6: ...nce Use only the 1 5m DC power cable supplied with the fridge freezer Important If a DC extension cable is required we recommended use of a 6mm dia AWG11 4 58mm2 Twin Sheath Two Core cable with direct connection to the positive and negative battery terminals with 15A inline fuse protection The fridge freezer is equipped with an electronic control system that will prevent polarity reversal In the e...

Page 7: ...C power source The fridge freezer will automatically turn on there is no requirement to switch the appliance on The display will automatically show the current internal cabinet temperature The fridge freezer is equipped with a multi voltage internal power supply with priority circuit for connecting to an AC voltage power source of 240V The power input socket is fitted with a 15A DC blade and a 5A ...

Page 8: ...ammed to maintain an average of the set temperature The compressor will start up when the internal cabinet temperature increases 0 5 to 1 5 degrees above the set temperature and will run until the temperature is 0 5 to 1 5 degrees below the set temperature BATTERY DISPLAY Voltage is measured at the input connection on the side of the appliance Values are for reference only and may be subject to ch...

Page 9: ... select Settings which will then display the control panel Make the required adjustments and then select Save Setting Select Back and the display will show the new settings To change the identifying name or password of your fridge from the factory settings you must first connect to the fridge Select Settings Select Modify Make the required changes then disconnect form the fridge Note The APP is de...

Page 10: ...ASHES current temperature setting 2 Press Up Down to set temperature 3 Display FLASHES for 3 seconds then returns to display ACTUAL temperature BATTERY MONITOR 1 Press MODE two times and current setting flashes 2 Press Up Down to select setting 3 Display FLASHES for 3 seconds and displays new setting COMPRESSOR SPEED 1 Press MODE three times and current setting flashes 2 Press Up Down to select se...

Page 11: ...Up Down to set temperature 4 Display FLASHES for 3 seconds then returns to display ACTUAL temperature TEMPERATURE SETTING ZONE 2 1 Press MODE twice to select Zone 2 2 Display FLASHES current temperature setting 3 Press Up Down to set temperature 4 Display FLASHES for 3 seconds then returns to display ACTUAL temperature BATTERY MONITOR 1 Press MODE three times and current setting flashes 2 Press Up...

Page 12: ...tness 100 CONSUMER SETTINGS When power is disconnected from the fridge for more than 10 minutes the system will return to factory settings POWER INPUT When connected to DC input the voltage is shown when connected to AC input the symbol of AC is displayed DOOR ALARM If the door is let open fro more then 1 minute an alarm will sound BATTERY MONITOR SETTING 1 Fridge to automatically restart once inp...

Page 13: ...TORS It is important that the correct generator size is used with your fridge freezer An incorrect generator or voltage output may result in reduced performance or damage to your fridge freezer which may void your appliance warranty If connecting directly to an AC generator ensure that only a digital or inverter type generator is used These provide a more reliable and constant 240V AC output power...

Page 14: ...d also be provided with suitable ventilation to guarantee efficient power consumption and performance You must remember that when a vehicle is parked in the sun on a day where the ambient temperature is 30 C the interior of the vehicle can reach 55 C Your fridge freezer will be delivered cleaned from the factory you nevertheless should clean prior to initial use Take a cloth which has been slightl...

Page 15: ...nit This is normal caused by the flow of refrigerant There is a noise from the unit Unit is not on a flat level surface Check for vibrations in surrounding objects Fridge Freezer does not work and display does not illuminate There is no voltage present in the 12V 24V cigarette lighter socket in your vehicle The ignition must be switched ON in most vehicles to apply current to the cigarette lighter...

Page 16: ...29L x 498W x 476Hmm Connections AC 220V 240V DC 12V 24V Current Draw average 5 6A 12V 3 0A 24V Cooling Range 10 to 18 C Power Input 80W Insulation PU Foam Compressor SECOP PBC2 0 SECOP PBC2 5 Thermostat Electronic control Material Metal cabinet lid and lining Certification SAA 140988 EA For further information or assistance please contact customer service on 1300 555 197 or email service companion...

Page 17: ...17 NOTES ...

Page 18: ...18 NOTES ...

Page 19: ...19 NOTES ...

Page 20: ...Distributed by Companion Brands Bundoora VIC 3083 www companionbrands com au COM5199 ...

Reviews: