background image

Mammoth Fans COMMERCIAL II SERIES     |      

19

18

TROUBLESHOOTING

TROUBLESHOOTING

Code

Desc.

Reason

Solution

E. iLF

Input  

missing

phase

Loosening of main circuit
terminal of controller

Tighten the screw and restart

Excessive input voltage
fluctuations

Improve the power supply to meet the rated voltage  
of the controller. If the main circuit power supply is  
fine, check the main circuit side of the electromagnetic 
contactor to identify the problem

Three-phase voltage
imbalance

Confirm if there is a problem with the input voltage  
and improve the power imbalance

Code

Desc.

Reason

Solution

E. oLFxx

Output  

missing

phase

Controller output side
U/V/W/ phase break

Check that the motor U/V/W/ phase connection is  
normal and check that the controller output terminal  
screw is not loose

Motor damage

Measure the resistance between the motor wires, and 
replace the motor immediately if it is connected

Low motor power

Reset controller or motor power

Code

Desc.

Reason

Solution

E. oL2

Controller

Overload

Overload

Reduce load
Increase the curve coefficient of overload protection of 
motor

Acceleration and deceleration 
time too short

Increase F01.22 F01.23 (acceleration and deceleration 
time) Decrease F04.01 (torque increase)

Torque lift set too large

Decrease F04.01 (torque increase)

V/F curve setting is not 
appropriate   

To determine the relationship between voltage and  
frequency of V/F curve setting, modify F04.00  
(VF curve setting) and modify the custom V/F curve  
related parameters (F04.10~F04.19)

Abnormal output current due to 
input missing phase

Check the main loop to remove input phase

Code

Desc.

Reason

Solution

E. oL1

Motor  

overload

Overload

Reduce the load and increase the curve coefficient of
overload protection

Acceleration and deceleration  
time set too small

Increase F01.22,F01.23  
(acceleration and deceleration time)

Torque lift set too large

Decrease F04.01 (torque increase)

V/F curve setting is not
appropriate

To determine the relationship between voltage and
frequency of V/F curve setting, modify F04.00  
(VF curve setting) and modify the custom V/F curve  
related parameters (F04.10~F04.19)

The characteristics of
electronic thermal relay are
inconsistent with the
characteristics of motor load.

Use of external thermal relays

Abnormal output current
due to input missing phase

Check the main loop to remove input phase

Code

Desc.

Reason

Solution

E. oH2

IGBT  

module

overheating

Excessive ambient temperature

Reduce the ambient temperature of the controller

Overload

Reduce load
Decrease F01.40 (carrier set)

Fan fault

Make sure that the fan is running normally.  
If not, replace the fan and start up again

Summary of Contents for COMMERCIAL II Series

Page 1: ...114 07 C A U T I O N R E A D I N S T R U C T I O N S C A R E F U L LY F O R S A F E I N S T A L L A T I O N A N D F A N O P E R A T I O N C O M M E R C I A L I I S E R I E S I N S TA L L AT I O N O PE...

Page 2: ...ensure that they do not play with the appliance 6 An all pole disconnection switch must be incorporated into the fixed wiring in accordance with local wiring rules 7 The structure to which the fan is...

Page 3: ...m cover 5 Aluminium alloy bushing 12 Blade components 6 Coil of wire 13 Extension tube 7 Fan controller CASE NO DIMENSIONS LxWxHmm Volume m3 Gross weight kg Remark 1 1400 x 600 x 310 0 16 70 Main body...

Page 4: ...Exclusively distributed by Beacon Lighting 7 6 5 Required installation tools PARTS LIST ADJUSTABLE WRENCH LASER DISTANCE MEASURE ALLEN KEYS WIRE CUTTER SOCKET WRENCH LEVEL MULTIMETER SCREW GLUE...

Page 5: ...r to the below diagram for detailed spacing requirement Secure the hanging bracket to the ceiling joist or structure with provided bolts and nuts Ensure there are 3 4 threads left on the bolt after ti...

Page 6: ...propriate electrical connection to the fan body ensure neat and tight connections are completed NOTE This is the steel wire bracket Please make sure it is installed before installing the fan motor par...

Page 7: ...FACE FUNCTION CODE DESCRIPTION EXPLANATION S00 Return Function can be used to return to the main interface If it doesn t return by this function it will automatically return to the main interface afte...

Page 8: ...s this could damage the fan and cause a safety issue 3 Ensure that the fitting does not come in contact with any organic solvents or cleaners 4 The motor has a permanently lubricated ball bearing whic...

Page 9: ...overcurrent fault Overload Reducing load or replacing impulse load of large capacity controller requires reducing load change frequency or replacing larger capacity controller Short circuit to the out...

Page 10: ...ncrease Torque lift set too large Decrease F04 01 torque increase V F curve setting is not appropriate To determine the relationship between voltage and frequency of V F curve setting modify F04 00 VF...

Page 11: ...arning If the error still occurs contact the Mammoth Fan support team Note where xx is self learning faults ub code Code Desc Reason Solution E oUxx Mid acceleration moderate midspeed stop over voltag...

Page 12: ...major failure Mammoth Fans cannot be held responsible for any repair other than those carried out by it or one of its Authorised Service Agents Please keep this warranty information in a safe place Th...

Page 13: ...C O M M E R C I A L I I S E R I E S...

Reviews: