AirCombi Spray Gun
MAMBA
Page 12
OPERATING MANUAL
8. Proper system setting
In order to obtain a proper atomization and a good finishing, below are the suggested set-up to apply on
the equipment’s settings and on the AirCombi Spray Gun’s settings.
1. Set the fluid pressure on the pump according to the product’s viscosity (from 0 up to 200 bar)
2. Set the gun air pressure on the pump according the fluid to spray
3. Adjust the Fan Regulator Set on the AirCombi gun if it is necessary to increase or decrease the fan width
8.1 Spring Tension Adjustment - Only for “A” Versions
Your AirCombi Spray Gun “A” Version is supplied with spring tension closed in order to meet standards for
safety. For a proper spraying it is necessary to set the Spring Tension Adjuster according to the pump pres
-
sure (Max. 200 Bar)
By reducing the pressure at the pump allows to open the adjustment screw of trigger tension accordingly.
Lower working pressure at the pump = Turn CCW the screw accordingly
Screw Spring Tension
Adjustment