MAM Easy Start Anti-Colic Quick Start Manual Download Page 2

6

Bottles & Bottle Accessories

Easy Start Anti-Colic

This product meets the requirements of European Standard EN 14350.

Instruction for use:

 Clean before first and each subsequent use.

 Before first use separate all 6 parts and place them in boiling water for 5 minutes. This is to ensure hygiene.

 Check all components before each use and throw away at the first signs of damage or weakness.

 To ensure proper cleaning/sterilising all bottle parts MUST be disassembled.

 Cleaning/sterilising while assembled can damage the bottle.
 Dishwasher safe on top dishwasher rack (max. 65° C / 149 F) but food colourings may discolour components 

 Do not use abrasive cleaning agents. Only soft bristle brushes or soft sponges should be used. Hard scourers may scratch the plastic.

 Sterilising using one of the following methods: steam sterilising (electric or microwave according to manufacturer’s instructions), boiling 

in water for at least 5 minutes or immersing in a liquid sterilising solution.

the function.

  Do  not  use  pin  or  sharp  object  to 

enlarge feeding hole of teat.

  When  first  used  and  sometimes 

during  use,  the  ventilation  slit  (in  the 

raised  bubble  on  the  underside  of  the 

teat  base)  can  stick  together.  This  will 

prevent  air  from  entering  the  bottle 

during  feeding  and  as  a  result,  cause 

the  teat  to  collapse.  Slowly  brush  over 

the bubble (ventilation) a few times with 

your thumb or fingers to re-open the slit. 

  Ensure  valve  is  assembled  correctly 

and  the  base  of  the  bottle  is  firmly 

attached prior to filling bottle with liquid 

(see figure 1, 2 &3).

 Do not let babies self-feed.

 Store teats and valves in a dry sealed 

container.

1

Place white silicone 
valve into bottom ring.

2

Press down on raised 

perimeter 

of silicone valve.

3

Screw assembled  

base onto bottom  

of bottle in slow steady 

manner.

4

Insert teat into top of 

bottle screw ring until 

you hear a ”click“.

7

Self-sterilising function of Easy Start:

The self-sterilising function of the Easy Start is proven to be effective for killing common household germs and bacteria. This method is 

completely sufficient and safe. For the best results, please follow all instructions carefully and use only as directed.

This practical and time-saving function can be achieved in 3 simple steps. Always thoroughly clean individual bottle parts before 

beginning this process!

Step 1:

 Assemble clean bottle parts as follows: base with silicone valve, teat with screw ring, 

bottle body and lid.

Step 2:

 Fill the base with silicone valve with 20 ml of cool water. The protective cap makes a 

practical measuring cup.

Step 3

: Place the screw ring with teat in the bottle base. Place the bottle body on it (optionally 

screw in slightly to avoid pouring out hot water by removing the bottle from microwave). Place the 

protective cap on top.

For your child’s safety and health

WARNING!

 Always use this product with adult supervision.

 Never use feeding teats as a soother.

 Continuous and prolonged sucking of fluids will cause tooth decay.

 Always check food temperature before feeding.

 Keep all components not in use out of the reach of children.

Sterilising in the microwave:

 Set the microwave timer according to the number of bottles being simultaneously cleaned. Set microwave from 500 to 1000 Watts.

 Allow bottle to cool down before removing from microwave. Recommended cooling time: 10 minutes at opened microwave door.

 Pour away the leftover water from the base. Allow bottle parts to dry.

 Always store bottle assembled.

Heating instructions:

 NEVER pour boiling water into the bottle.

 Place in a bottle warmer, under hot running water or in a container of heated water

 NEVER heat or cool a sealed bottle. Remove the protective cap and teat (with screw ring) before heating, especially before bottle warmer 

and microwave heating. Do not overheat as this may damage the bottle.

 Take care when heating in the microwave.

 Stir thoroughly after heating to evenly distribute heat. Allow the standing time recommended by the microwave manufacturer. Test the 

temperature before serving.

 Wrap cloth or towel around bottom of bottle and shake to absorb any excess water after warming in a bottle warmer or boiling water.

 After warming the bottle in a bottle warmer or boiling water it is recommended to tighten the bottom of the bottle.

 Do not place bottle in heated oven.

 Do not leave single bottle parts in direct sunlight or heat.

 Always use only MAM teats with the MAM bottles.

 Use only sugar free food or liquids.

 To avoid injury, do not let baby walk with bottle.

 Do not put your baby to bed with bottle. Prolonged contact with liquids may cause severe tooth decay.

 Bottle teat fits all MAM wide neck bottles and the Trainer.

3

2

1

Number of bottles 
sterilised at the same 
time

Estimated duration 
of sterilising [min]

1

3

2

4

3

5

4

6

5

7

6

8

After the process is complete, the Easy Start bottle remains disinfected up 

to 

48 hours

 after self-sterilising in the microwave, provided that it stays 

assembled as shown on Step 3.

Reviews: