background image

IMPULSE KL

SERIES

INSTRUCTIONS FOR USE

CLINIC DESIGN

Summary of Contents for Impulse 300 KL

Page 1: ...IMPULSE KL SERIES INSTRUCTIONS FOR USE CLINIC DESIGN...

Page 2: ...2...

Page 3: ...le maintain ing the highest standards of safety We would like to thank you for the trust you have placed in us Our company guarantees carefully selected materials and continuous quality control while...

Page 4: ...on of function 18 Back rest 18 Mechanical release of the Back rest CPR 18 Upper leg section 18 Height adjustment 18 Transfer position 19 Low position Fall prevention 19 Comfort sitting position 19 Aut...

Page 5: ...d controller 27 Mattresses 27 Side rail heightening 27 Urine bottle bag basket 28 5th wheel 28 Trouble shooting 30 Product safety 31 Cleaning and disinfection 32 Maintenance 33 Storage 33 Warranty and...

Page 6: ...6 Room representation Impulse 300 KL Impulse 400 KL...

Page 7: ...ion positioning and relief of disabilities for treated patients in hospitals and care facilities If the clinical beds are used for other applications then prior written agreement from Betten Malsch Gm...

Page 8: ...pulse KL clinical bed range The images graphics and text it contains may differ from the delivered equipment The manufacturer offers technician training for maintenance and servicing work on their cli...

Page 9: ...to ensure that the patient does not come into contact with the side rails when adjusting the lying posi tion to avoid trapping any part of the body 9 The side rails must be taken down every day to che...

Page 10: ...er and also avoid any potential damage to the bed The mattress used must fulfill the applicable safety standards For safety reasons the handle on the trapeze bar should be replaced completely every 5...

Page 11: ...nce a year These inspections may only be carried out by an electrical specialist or someone with elec trical training using a special measurement and inspection device Inspections in accordance with B...

Page 12: ...KL approx 27 bis 80 cm Impulse 300 KL XL KL approx 36 bis 86 cm Backrest adjustment 71 reclining angle for backrest 12 cm mattress compensation Upper leg adjustment 43 Trendelenburg 14 Antitrendelenb...

Page 13: ...cal check after delivery in ac cordance with VDE0751 1 Typical illustration of a rating plate on an Impulse 300 KL clinical bed standard design with mains connection 7 Explanation of the terms used on...

Page 14: ...eg rest adjustment up S5 Auto contour up S7 Lift adjustment up S9 Low positioning1 S4 Leg rest adjustment down R1 BLOCKED No functions operational R2 FREE All functions available R3 FREE All functions...

Page 15: ...djustment down S17 Auto contour down S18 Lift adjustment down S19 Trendelenburg position BLOCKING FUNCTIONS S3 Back rest adjustment block S4 Leg rest adjustment block S5 Auto contour block S6 Lift adj...

Page 16: ...16 Impulse 300 KL optional equipment Impulse XL KL Impulse 400 KL P R O D U C T D E S I G N A T I O N...

Page 17: ...both left right Bed panel Nurse s control panel Telescopic bed linen storage Adjustable lower leg rest Mount for IV holder and accessories Foot pedal with central brake 6 and fixed direction 5 of the...

Page 18: ...n the design and type of clinical bed the bed can be put into the following positions by adjusting the back rest the upper leg and the lower leg sections as well as the height of the bed Back rest Use...

Page 19: ...st ensure that the lowered splitted side rails are retracted F p 22 Fig 1 and that there is nothing under the bed Comfort sitting position Use the corresponding button on the hand controller to set th...

Page 20: ...lifting mechanism This function must only be used by specialist staff and must be locked by specialist staff on the back of the hand controller Faulty settings can lead to serious injury to the patie...

Page 21: ...odel has 3 differ ent possible settings 1 Central locking of the castors foot pedal down 2 4 castors released 360 foot pedal in the middle 3 1 castor fixed direction foot pedal up Caution The clinical...

Page 22: ...e rails to a mid height position with a tilting action to raise the side protection This position is particularly suitable as a mobility support when moving the patient 3 For height adjustment and for...

Page 23: ...le doing so pull them towards you 2 Pull the bed extension out fully and position the mattress insert 3 Now push the bed extension back in without using the pedal until you hear it lock An intermediat...

Page 24: ...eased and removed from above using the quick connector on the bed frame mounting green lever Caution Ensure that the head foot boards are locked before using the bed Caution Secure the patient before...

Page 25: ...d staff for the assembly of head foot boards lying surfaces as well as the installation replacement of lying surface motors After completion of service and maintenance work the functionality of electr...

Page 26: ...erted into the designated mount ing sockets in the lying surface frame either left or right of the head foot end The intravenous drip stand is only designed for hanging IV drips not for attaching othe...

Page 27: ...made spe cial mattresses for the widest range of applications and de mands on lying surface contours of clinical beds Please ask your specialist retailer of the manufacturer for the right mat tress fo...

Page 28: ...to a col lision with other bed parts or other equipment within the room 5th wheel The centrally placed 5th wheel makes rotation of the bed eas ier during patient transport It is locked using the foot...

Page 29: ...29...

Page 30: ...g load has been exceeded Reduce the load Motors cut out after a longer pe riod of operation The adjustment time or safe working load has been exceeded and the control unit has reacted to overheating A...

Page 31: ...ISO 14971 Risk analysis DIN EN 12182 Assistive products for persons with disability DIN EN 60601 2 52 Medical electrical equipment DIN EN 60601 1 Medical electrical equipment DIN EN 60601 1 2 EMV elec...

Page 32: ...Med or equivalent detergents for disinfection The detergents used for disinfection must only be used in accordance with the manufacturer s instructions Caution Under no circumstances use abrasives cle...

Page 33: ...d reliability of the product if it is maintained regularly and used in accord ance with the safety instructions If any significant faults are found during maintenance work which mean the safe opera ti...

Page 34: ...d you will receive a replacement or have the fault repaired free of charge This excludes faults and errors caused by inappropriate handling or external influences Our normal terms of business and deli...

Page 35: ...n was conducted in accordance with the T V PROFiCERT auditing and certification procedures and is subject to regular surveillance audits Verifiable under www tuev club de Original certificates contain...

Page 36: ...Edition 10 2019 Rev 1 4 Colours may vary Technical modifications reserved Betten Malsch GmbH Rohbergstra e 9 36208 Wildeck Obersuhl GERMANY Phone 49 0 6626 915 100 Fax 49 0 6626 915 116 bettenmalsch...

Reviews: