A charge will be made for work done or service call where: 

 

There is nothing wrong with the unit. 

 

The defective operation of the unit is due to failure of electricity or water supply. 

 

Defects are caused by neglect, incorrect application, abuse or by accidental damage of the 
unit. 

 

An unauthorised person has attempted to repair the unit. 

 

Harsh environmental situations such as water quality that may cause the water tank damage 
can not be considered warranty. 

 

Claims for damage to contents, carpet, ceilings, foundations or any other consequential loss 
either direct or indirect resulting from, power spikes, incorrect operation, incorrect installation or 
faulty product are excluded. 

 

All warranties are NOT transferable. 

 

Unauthorised use of non-genuine Malmet Parts in units covered by Warranty will void all 
warranty and warranty claims. 

 

To the extent permitted by law Warranty labour (service work) shall not include units located 
outside of city metropolitan areas and costs outside these areas shall be borne by the 
Customer.  The Customer shall be notified of this prior to the warranty call out. 

Warranty on Replacement Parts 

Parts replaced under warranty are warranted for the balance of the original warranty period for that 
product. 
 

Unit Components 

Parts 

Labour 

Structural Guarantee 

All other components 

 

 

Date Sold:  ...................................  

Warranty Expiry Date:  ...................................  

 

Sold To: 

For Service Contact: 

 

 

 

 

 

 

 

Summary of Contents for Drying Cabinet

Page 1: ......

Page 2: ...of Contents Forward 3 Design Parameters 3 Quality Policy 4 Section A Unit Operation 5 Section B Unit Maintenance 6 Trouble Shooting Guide 7 Wiring Diagram 8 Section C Unit Installation 9 Unit Specific...

Page 3: ...r tubing face masks anaesthetic bags and other ancillary equipment A total of six 6 stainless steel shelves is provided The shelves are removable with 6 positions including the base The cabinet is ins...

Page 4: ......

Page 5: ...net appears for approximately five seconds After five seconds the unit switches to display the actual cabinet temperature Changing the set temperature lock out feature AUTHORISED PERSONNEL ONLY Author...

Page 6: ...m water and detergent Wipe over outside panels with stainless steel cleaner Weekly Remove filter on air intake top right hand side panel and wash in warm water and replace when dry Half Yearly Check e...

Page 7: ...turns off Fan failure Switch off power supply at main and Call for Service Display is on but unit not heating Element failure Relay board failure Switch off power supply at main and Call for Service...

Page 8: ...Drying Cabinet Operation Maintenance and Installation Manual Issue 15 Page 8 7th October 2011 Wiring Diagram...

Page 9: ...be a 5 to10mm gap between the side panel and the timber Clearance on the top of the Drying Cabinet needs to be typically 500mm This allows access to replace the electric motor heating elements etc All...

Page 10: ...B SKCM325 Access via compatible RS232 Control PCB Overtemp Protection Electronic cutout 5 C above set point Temperature Control Incremental 1 C 70 C Factory set at 70 C Secondary Overtemp Protection H...

Page 11: ...ltered Parts damaged in transit back to Malmet Leeton due to poor packaging could result in warranty claim being rejected Any part tampered with or has unauthorised repairs and modifications will be r...

Page 12: ...tial loss either direct or indirect resulting from power spikes incorrect operation incorrect installation or faulty product are excluded All warranties are NOT transferable Unauthorised use of non ge...

Page 13: ...installer is responsible for the correct installation start up and demonstrating the operation of this product They are also responsible for issuing the relevant certificates of compliance These may...

Page 14: ......